EasyManua.ls Logo

Panasonic KX-TES824LA - SPECIFICATIONS; General Description; Characteristics; System Capacity

Panasonic KX-TES824LA
289 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 SPECIFICATIONS
4.1. GENERAL DESCRIPTION
Control Bus Original bus (16-bit, 24 MHz)
Switching Space Division CMOS Crosspoint Switch
Power Input 100 V AC to 240 V AC, 1.5A to 0.75A, 50 Hz/60Hz
External Battery +24 V DC (+12 V DC x 2)
Maximum Power Failure Tolerance 300 ms (without using backup batteries)
Memory Backup Duration 7 years
Dialling Outside (CO) Line Pulse (10 pps, 20 pps) or Tone (DTMF)
Extension Pulse (10 pps, 20 pps) or Tone (DTMF)
Intercom Path 4
Mode Conversion Pulse-DTMF
Ring Frequency 20 Hz/25 Hz (selectable)
Operating Environment Temperature Cto4C
Humidity 10 % to 90 % (non-condensing)
Conference Call Outside (CO) Line 2
Music on Hold (MOH) 1 port
Selectable MOH: Internal/External/Tone
Paging Internal 1
Extension 1 port
Serial Interface Port RS-232C 1
USB 1.1 1
Extension Connection Cable SLT 1 pair wire (T, R)
PT 2-pair wire (T, R, H, L)
DSS Console 1-pair wire (H, L)
Dimension 368 mm (W) x 284 mm (H) x 102 mm (D)
Weight (when fully expanded) Approx. 3.5 kg
4.2. CHARACTERISTICS
Terminal Equipment Loop Limit PT 40
SLT 600 including set
Doorphone 20
Minimum Leakage Resistance 15000 minimum
Maximum Number of Extension
Instruments per Line
1 PT or SLT in standard connection
1 PT and 1 SLT in parallel connection
Ring Voltage 75 Vrms at 20 Hz/25 Hz depending on the ringing load
Outside (CO) Line Loop Limit 1600 maximum
Hookswitch Flash/Recall Timing Range 24 ms-2032 ms
Door Opener Current Limit 30 V DC/125 V AC, 3 A maximum
Paging Terminal Impedance 600
MOH Terminal Impedance 10000
4.3. SYSTEM CAPACITY
4.3.1. System Capacity
KX-TES824 KX-TEM824
Basic System Outside (CO) lines 3 6
Extensions 8 16
Fully Expanded System Outside (CO) lines 8 8
Extensions 24 24
9
KX-TES824LA / KX-TEM824LA /

Related product manuals