8
5.3. Power Cord U / Circuit Breaker
1. Remove the Screw (4x10) which fixes the Motor
Complete, and remove the Lead Wire (Yellow).
2. Move the 2 Insulation Tubes from the Circuit
Breaker, remove the faston terminals of Lead Wire
A (U) and Power Cord (U), and remove the Circuit
Breaker.
Assembly Instructions
Attach the Lead Wire to the Circuit Breaker, and
set Insulation Tubes firmly.
3. Melt the solder which fixes the Lead Wire (Black) on
Switch Complete B, and remove the Power Cord
(U).