Troubleshooting
Before calling a service supplier,
please check the following possible causes.
If... Possible cause Howtox
White or glittering
akesoatingin
the hot water.
Rough milky white
substancess are
adhered to inner
container.
●
The cause of this is “scale”. (see P.14)
It is not akes of uororesin.
* Water with a large content of minerals in it
such as mineral water or ionized water, is
more likely to cause a scale or white layer in
the hot water.
●
Clean the inner container with a
wet soft sponge. (See P.14)
●
If the “scale” still remains, clean
with citric acid. (See P.15)
Boiling sounds
become louder.
●
When “scale” adheres, boiling sounds become
louder.
Hot water has
odors of chlorine.
●
Odors of chlorine remain depending on the
amount of chlorine in tap water.
●
Press key to reduce the
chlorine. (See P.10)
Hot water has an
unpleasant odor.
●
When the unit is new, resin used in the manufacturing process may give off a mild odor.
This will disappear with use.
●
If the unit is placed on surfaces such as a vinyl sheet, the odor may be carried over into the
water.
Hot water comes
out by itself.
●
Water has been added above maximum water
level.
●
Lower the water level.
Hot water does not
owoutsmoothly.
●
The mesh lter may be clogged with “scale”.
(See P.14)
●
When scale is accumulated in the inner container
and remaining hot water is low, hot water does
not ow out smoothly.
●
Immediately after boiling, hot water may not ow
out smoothly.
●
Clean the lter with a brush.
●
If the “scale” cannot be removed,
replace the lter (See P.17)
The indicator lights
ashalternately.
●
Overheating protection has been activated
(See P.9)
●
Add water and press key.
●
The indicator lights may ash alternately by
adding boiling water or the way the water is
supplied.
●
Press key.
●
When the inner container is cleaned with citric
acid, citric acid has built up on the bottom.
●
Disconnect the plug, and stir the
citric well to dispose.
Hot water does
not dispense.
●
The automatic lock has been engaged.
●
Press key.
●
If the problem is not xed after checking the above possible causes, or if you think something is strange, disconnect the
body plug from the unit. Wait at least 10 seconds and then re-connect the plug.
●
The semi-transparent inner part inside the lid may become yellowish. This does not affect operation of the unit.
●
The rattling noise in the lid is made by small ball-shaped components which prevent water from ooding out
if the unit topples over.
●
If the room temperature is very high, the outside of the main unit may reach about 55°C.
The unit does not
turn on.
●
You poured in water directly from a tap.
●
It is broken if the electric
components are immersed in
water.
Contact the store where you
purchased the unit for repair.
●
You put the unit on the sink.
●
You turn the unit upside down with its bottom wet.
●
You washed the unit in water.
“Reboil” and “80”
indicator lights
ashalternately.
●
This is malfunction of the sensor.
●
Contact the stores where you purchased.
Troubleshooting
01_NC-EG4000_3000_2200_PZ05H6934_EN.indd 1601_NC-EG4000_3000_2200_PZ05H6934_EN.indd 16 6/4/2566 BE 14:216/4/2566 BE 14:21

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic NC-EG3000 and is the answer not in the manual?

Panasonic NC-EG3000 Specifications

General IconGeneral
Volume3 L
Temperature (min)70 °C
Adjustable temperatureYes
One-liter glasses capacity- L
Product colorPink, White