EasyManua.ls Logo

Panasonic NN-S245 - Page 13

Panasonic NN-S245
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RATED OUTPUT TEMPERATURE RISE
1100W Min. 16.9°F(9.4°C)
1200W Min. 18.5°F(10.3°C)
3. PROCEDURE FOR MEASURING MICROWAVE
ENERGY LEAKAGE
WARNING
Check for radiation leakage after every servicing.
Should the leakage be more than 2 mW/cm
2
(1mW/
cm
2
for Canada) inform PASC, PSC, or PCI
immediately. After repairing or replacing any
radiation safety device, keep a written record for
future reference, as required by D.H.H.S. and Health
and Welfare Canada regulation. This requirement
must be strictly observed. In addition, the leakage
reading must be recorded on the service repair
ticket while in the customers home.
NOTE:
The U.S. Government standard is 5 mW/cm
2
while in the customers
home. 2mW/cm
2
stated here is our own voluntary standard. (1mW/
cm
2
for Canada)
3.1. Equipment
- Electromagnatic radiation monitor
- Glass thermometer 212°F or 100°C
- 600cc glass beaker
3.2. Procedure for measuring radiation leakage
Note before measuring.
- Do not exceed meter full scale deflection. Leakage monitor should
initially be set to the highest scale.
- To prevent false readings the test probe should be held by the grip
portion of the handle only and moved along the shaded area in
Figure no faster than 1 inch/sec (2.5cm/sec).
- Leakage with the outer panel removed ...... less than 5mW/cm
2
.
- Leakage for a fully assembled oven with door normally closed ......
less than 2mW/cm
2
(1mW/cm
2
for Canada).
- Leakage for a fully assembled oven [Before the latch switch
(primary) is interrupted] while pulling the door ...... less than 2mW/
cm
2
.
13