EasyManua.ls Logo

Panasonic NN-S245 - Defrosting Operations

Panasonic NN-S245
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Follow the matrix table below to identify the problem source.
Note:
Do not replace both Inverter board and Magnetron simultaneously
and automatically without going through this procedure.
Power will: Ammeter reading is: To do: Remedy:
Shut off in 23
seconds after
Start.
1. Between 0.5A and 1.0A. Check and repair open
magnetron circuit
Open magnetron
wiring
between Inverter
and
magnetron terminal.
2. Between 1.0A and 2.0A. Check continuity of D702 in
Inverter PCB.
1. D702 shorted Replace H.V.Inverter
(F606Y6G00AP/
F606Y6G00CP)
2. D702 is OK Replace magnetron
Shut off in 3
seconds after
Start”
1. Less than 0.5A Check open circuit: Latch
Switch, DPC, Power Relay and
CN701
Replace defective
component(s), or
correct
switch, cables and
connectors.
5. H.V.INVERTER BOARD MAIN PARTS LIST
(F606Y6G00AP/F606Y6G00CP)
Ref. No. Part No. Part Name & Description Pcs/Set Remarks
C707 ECWH30822JUA CAPACITOR 1 8200PF,3000VDC
C706 ECWH30562JUA CAPACITOR 1 5600PF,3000VDC
D701,D702
B0FBAZ000001 DIODE SI 2
DB701 B0FBBS000001 BRIDGE DIODE 1 20A,600V
L701 F50206G00AP CHOKE COIL 1
Q701 B1JAGV000008 TRANSISTOR SI 1 900V
T701 A609A6G00AP H.V. TRANSFORMER 1
6. EXPLODED VIEW AND PARTS LIST
6.1. EXPLODED VIEW
16

Table of Contents

Other manuals for Panasonic NN-S245