B. During oven operation, input current is approximately less than
0.4A.
INPUT AMPERE FAILURE CODE
Unplug CN701 <0.4A Oven stops in 3
seconds after
started.
If both a and b are OK, the Inverter Power Supply (U) can be determined OK.
11. MEASUREMENTS AND ADJUSTMENTS
11.1. Adjustment of primary latch switch, secondary latch switch and
short switch.
1. When mounting Primary latch switch,Secondary latch switch and
short switch to door hook assembly, mount the Primary latch switch,
the Secondary latch switch and the short switch to the door hook
assembly as shown in table.
NOTE:
No specific adjustment during installation of Primary latch switch,
Secondary latch switch and short switch to the door hook is
necessary.
2. When mounting the door hook assembly to the oven assembly, adjust
the door hook assembly by moving it in the direction of arrow in the
illustration so that the oven door will not have any play in it. Check for
play in the door by pulling the door assembly. Make sure that the latch
keys move smoothly after adjustment is completed. Completely
tighten the screws holding the door hook assembly to the oven
assembly.
3. Reconnect the short switch and check the continuity of the monitor
30