6. SELF DIAGNOSING FUNCTION
When abnormalist is cased in the refrigerator, the sign is displayed on LED as below chart.
How to use “Self Diagnosing” function
1. Opening PC door and FC door,
Push “Quick Freezing” bottom more than 5 sec.
2. After blinking at sec., each LED show as below.
3. “Self Diagnosing” function will be automatically
cancel after 7 min., from start operation.
Lighting Blinking Off
ECONAVI
LED
QUICK LED
FC CONTROL LED
MAX MED MIN
FCC
DFC
ATC
FC FAN MOTOR
DEFROST HEATER
INV COMP
PCB
HC LEAK (HIGH PRESSURE)
HC LEAK (LOW PRESSURE)
ILLUMINANCE SENSOR
“Freezer Control” button
“Quick Freezing” button
Quick Freezing
Freezer Control