Simple Power On Sequence (FX/FS/FZ Series)
Power SW on / Remote on
< Display start >
( Plug in )
49
Power Off
StandbyPower On
16V / 64V(*) /24V(OLED) output / PFC circuit start working
TV_SUB_ON signal
STB5V output
Stop 16V / 64V(*)
PNL12V output
PANEL_VCC_ON signal
Power LED Green
Stop 16V / 64V(*)
Power LED off
TV_SUB_OFF TV_SUB_OFF
AC Plug in
STB5V (form P to A)
16V (from P to A)
PNL12V (from A to Panel(T-CON) )
SUB_ON (from A to P)
Power LED
Panel_Vcc_ON (from A to Panel(TCON))
VLED (from P to Panel(Backlight) )
BL_ON/EVDD_ON (from A to P/LDP/PB)
(Standby)
Power on
(Standby)
Power on
Power on
North America :
(Power LED Green RED)
(Power LED Red OFF)
(Power Off no exist)
Also 16V is necessary before Power LED.
Standby / Power on
5V
16V
12V
ex.64V(*)
VLED,
ex. 120V
64V(*) up to VLED
BL_ON_ON signal
< FX/FS/FZ series >
Power LED Red
(*) The DC level is different by the LCD panel.
< Display start >
24V output
EVDD_ON_ON signal
FZFX/FS
FX/FS
24V (from P/PB to Panel(T-CON))
FZ
24V
output to T-CON