1. SAFETY PRECAUTIONS
 GENERAL GUIDELINES
1.  IMPORTANT SAFETY NOTICE
There are special components used in this equipment which are 
important for safety. These parts are marked by   in the 
Schematic Diagrams, Circuit Board Layout, Exploded Views and 
Replacement Parts List. It is essential that these critical parts 
should be replaced with manufacturer's specified parts to prevent 
X-RADIATION, shock, fire, or other hazards. Do not modify the 
original design without permission of manufacturer.
2. An Isolation Transformer should always be used during the 
servicing of Combination VCR whose chassis is not isolated from 
the AC power line. Use a transformer of adequate power rating as 
this protects the technician from accidents resulting in personal 
injury from electrical shocks. It will also protect Combination VCR 
from being damaged by accidental shorting that may occur during 
servicing.
3. When servicing, observe the original lead dress, especially the 
lead dress in the high voltage circuits. If a short circuit is found, 
replace all parts which have been overheated or damaged by the 
short circuit.
4. After servicing, see to it that all the protective devices such as 
insulation barriers, insulation papers, shield, and isolation R-C 
combinations are properly installed.
5. Before turning the receiver on, measure the resistance between B+
 line and chassis ground. Connect (-) side of an ohmmeter to the B
+ lines, and (+) side to chassis ground. Each line should have 
more resistance than specified, as follows :
(Model: A, B, C, D, E, F, G)
B+ Line
Minimum Resistance
115 V
1 k   (Cold chassis ground)
24 V
2