7.3.7.2.2. How to release from EVR Adjustment Mode:
Press and hold STOP, PLAY, and VOL DOWN buttons on the unit together over 5 seconds again
or press the POWER button OFF.The adjusted value will be written to Memory IC (IC6004).
7.3.7.3. HOW TO ENTER EVR PG SHIFTER ADJUSTMENT MODE
1. Enter EVR adjustment mode.
2. Insert the VHS Alignment Tape and playback in SP mode.
The adjustment overlay will appear.
Fig. E5-6
7.3.7.3.1. How to adjust:
Press CH UP/DOWN key on the remote control to adjust the value.
Fig. E5-7
7.3.7.3.2. How to release from EVR PG Shifter Adjustment Mode:
Press STOP button or press the POWER button OFF.
The adjusted value will be written to Memory IC (IC6004).
7.3.7.4. HOW TO ENTER SERVICE MODE
1. Enter EVR adjustment mode.
2. Press DISPLAY key on the remote control for collapse scan.
Note:
Before pressing DISPLAY key on the remote control for collapse
scan, select the desired control function and move the shaded area
to the value for adjustments you will proceed.
Fig. E5-8
7.3.7.4.1. How to release from Service Mode:
Press DISPLAY key again on the remote control.
7.3.8. PG SHIFTER ADJUSTMENT
64