The Simplified Fault finding data is stored in the Memory IC (IC6004). This data is cleared after it
is displayed, and then the POWER button is pressed back on.
1. With power turned off, press FF and REW buttons on unit together
for over 3 seconds.
Fig. 1-1
2. TV power goes on and the unit goes into service mode.
4 digit for fault code and communication for I2C bus code will be
displayed.
Fig. 1-2