22
To accomplish MMC operation, the MIDI channel of the WR-DA7 and the MIDI channel of the BRC
must be set to the same channel. On the BRC, obtain a display of 11: MIDI Device screen by
MIDI/UTIL setting. Set the value of ‘MIDI channel set for the WR-DA7 - 1.’ Otherwise, the settings
should be set to ‘ALL.’
BRC setting (BRC as the wordclock slave)
When using a BRC and ADAT with the DA7, it may be necessary to sync the BRC to the DA7’s inter-
nal wordclock generator.
1. Connect a 75 ohm (BNC) wordclock cable from the DA7’s wordclock output to the BRC’s 48
kHz input.
2. Press the EDIT then EXTERNAL sync buttons on the BRC and using the arrow keys, select 48
kHz INPUT.
3. Press the EDIT button to go back to normal operation. Make sure the EXTERNAL sync button
is enabled (the button lights green).