EasyManua.ls Logo

Panasonic RAMSA WR-DA7 - Connection to MAX (Macintosh) Expansion Software

Panasonic RAMSA WR-DA7
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
52
3.14 Connection to MAX (Macintosh) expansion software
The example refers to the building of a recording and mixing automation system using one WR-
DA7 and the expansion software of a personal computer. By using the expansion software, the
faders, EQ, PAN, and channel ON/OFF of the WR-DA7 can be separately controlled in synchroniza-
tion with the MIDI timecode. The setup data of the WR-DA7 can be uploaded to and downloaded
from the expansion software.
Connecting Procedures
Connect the modem port of the Macintosh computer to the [To PC] port of the WR-DA7 using a
Macintosh serial cross cable (ImageWriter printer cable).
For the MMC control of the DA-98 serving as the timecode master from the WR-DA7, connect the
MIDI OUT of the WR-DA7 to the MIDI IN of the DA-98 and MIDI IN of the WR-DA7 to MIDI OUT of
the DA-98 using standard MIDI cables.
This system uses the DA-98 as the wordclock master and synchronizes the WR-DA7 with the WR-
TDIF card, therefore no word clock connection is necessary
WR-DA7 Setup
This system uses the DA-98 as word clock master. The WR-DA7 is synchronized with the DA-98
that is connected to Slot 1. So, set [Source Select] to [Slot 1] on the D-I/O input set screen.
To receive MTC from the DA-98 and make the expansion software through, set [MTC Port] to
[MIDI] and [THRU] in the item [Others] to [ON]. Since the MMC is being transmitted from the
WR-DA7 to the DA-98, set the [MMC Port] to [MIDI] and match [MIDI CH] with the MIDI/bus ID of
the DA-98.
PC (Macintosh) Setup
If Free MIDI is installed, there is a possibility of a conflict. It is recommended that it be removed
using the computer's extension manager.
Expansion Software Setup
Select [Preference] from the Edit menu and open the dialog. Select [Port Setup] in the dialog, and
set the [Automation Port] to [Modem].
Similarly, select WR-DA7 Timecode Input as Sync Source in the Preference Port Setup menu. Then,
check [Receive Timecode] on the Real-time menu. It is now ready to receive MTC from the DA-98
via the WR-DA7.

Other manuals for Panasonic RAMSA WR-DA7