EasyManua.ls Logo

Panasonic S-140MT2E5A User Manual

Panasonic S-140MT2E5A
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Operating Instructions
Air Conditioner
4-Way Cassette
(U1 type)
Low Silhouette Ducted
(F2 type)
Ceiling
(T2 type)
Model No.
INDOOR UNIT
4-Way Cassette
(U1 type)
S-22MU1E5A
S-28MU1E5A
S-36MU1E5A
S-45MU1E5A
S-56MU1E5A
S-60MU1E5A
S-73MU1E5A
S-90MU1E5A
S-106MU1E5A
S-140MU1E5A
S-160MU1E5A
Ceiling
(T2 type)
S-36MT2E5A
S-45MT2E5A
S-56MT2E5A
S-73MT2E5A
S-106MT2E5A
S-140MT2E5A
Low Silhouette Ducted
(F2 type)
S-15MF2E5A
S-22MF2E5A
S-28MF2E5A
S-36MF2E5A
S-45MF2E5A
S-56MF2E5A
S-60MF2E5A
S-73MF2E5A
S-90MF2E5A
S-106MF2E5A
S-140MF2E5A
S-160MF2E5A
Connectable outdoor unit lineup
This booklet is the operating instructions
for indoor unit. Regarding the outdoor
unit, see the operating instructions
supplied with the outdoor unit.
OUTDOOR UNIT
mini VRF
(LE1 type)
U-4LE1E5
U-5LE1E5
U-6LE1E5
U-4LE1E8
U-5LE1E8
U-6LE1E8
2WAY VRF
(ME1 type)
U-8ME1E81
U-10ME1E81
U-12ME1E81
U-14ME1H81
U-16ME1E81
U-18ME1E81
U-20ME1E81
3WAY VRF
(MF2 type)
U-8MF2E8
U-10MF2E8
U-12MF2E8
U-14MF2E8
U-16MF2E8
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
F569617
ENGLISH
2 ~ 9
Before operating the unit, read these operating instructions thoroughly and
keep them for future reference.
FRANÇAIS
10 ~ 17
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et
conservez-le pour toute référence ultérieure.
ESPAÑOL
18 ~ 25
Antes de operar la unidad, lea atentamente estas instrucciones de
funcionamiento y guárdelas para futuras consultas.
DEUTSCH
26 ~ 33
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese
Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die
künftige Verwendung auf.
ITALIANO
34 ~ 41
Prima di utilizzare l’unità, leggere a fondo queste istruzioni per l’uso e
conservarle come riferimento futuro.
NEDERLANDS
42 ~ 49
Lees deze gebruiksinstructies goed door voor u het apparaat gebruikt en
bewaar ze voor toekomstig gebruik.
PORTUGUÊS
50 ~ 57
Antes de utilizar o aparelho, leia completamente este manual de instruções
e guarde-o para futuras referências.
EΛΛΗΝΙΚΆ
58 ~ 65
Πριν θέσετε τη μονάδα σε λειτουργία, διαβάστε πολύ καλά αυτές τις οδηγίες
χρήσης και διατηρήστε τις για μελλοντική αναφορά.
БЪЛГАРСКИ
66 ~ 73
Преди да започнете експлоатация на този уред, прочетете внимателно
тези инструкции и ги запазете, за да можете да правите справки с тях и
в бъдеще.
РУССКИЙ
74 ~ 81
Перед использованием этого устройства внимательно прочитайте
настоящую инструкцию по эксплуатации и сохраните ее для
дальнейших справок.
УКРАЇНСЬКА
82 ~ 90
Уважно прочитайте цю інструкцію з експлуатації перед тим, як
увімкнути пристрій, та збережіть її на майбутнє.
B.INDONESIA
91 ~ 99
Sebelum mengoperasikan unit, baca petunjuk pengoperasian ini secara
menyeluruh dan simpan untuk referensi mendatang.
ENGLISH
FRANÇAIS
ESPAÑOL
DEUTSCH
ITALIANO
NEDERLANDS
PORTUGUÊS
EΛΛΗΝΙΚΆ
БЪЛГАРСКИ
РУССКИЙ
УКРАЇНСЬКА
B
.INDONESIA
OI_F569617_EU_L.indb 1 2013-12-17 17:57:32

Table of Contents

Other manuals for Panasonic S-140MT2E5A

Questions and Answers:

Panasonic S-140MT2E5A Specifications

General IconGeneral
BrandPanasonic
ModelS-140MT2E5A
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Precautions

General Safety Warnings

Crucial warnings covering ventilation, flammables, electrical contact, and user actions.

Electrical Safety Guidelines

Instructions on power outlets, grounding, and circuit protection for electrical safety.

Operational Safety and User Responsibility

Advice on stopping during abnormalities, avoiding self-repair, and proper appliance use.

Appliance Usage and Environment

Guidance on suitable users, operating environments, and safety distances.

Refrigerant Information

Details on the refrigerant type used and its environmental implications.

Precautions for Use

Installation and Wiring Requirements

Essential steps for installing the unit, including location, electrical codes, and grounding.

Operation Preparation and Conditions

Pre-operation steps like power supply duration and recommended operating temperature ranges.

Waste Disposal and Recycling

Instructions for the responsible collection and disposal of old equipment and batteries.

Names of Parts

Indoor Unit Component Identification

Identifies key components of U1, F2, and T2 indoor unit types.

Optional Remote Controllers

Lists available wireless, timer, and wired remote controller models for operation.

Operation Mechanism

Heating, Defrosting, and Dry Modes

Explains heating performance, automatic defrosting, and the 'Dry' operation mode.

Power Failure and Recovery

Describes how the unit behaves and recovers after a temporary power interruption.

Adjusting Airflow Direction

Vertical Airflow Adjustment

How to adjust vertical airflow using timer and wireless remote controls.

Recommended Vertical Airflow Settings

Guidance on optimal vertical airflow settings for heating and cooling.

Horizontal Airflow Adjustment (T2 Type)

Manual adjustment of horizontal airflow vanes for the T2 type unit.

Multi-Unit Airflow Control

Individual Unit Airflow Setting

Adjusting airflow direction for each indoor unit when using one remote.

Simultaneous Unit Airflow Setting

Adjusting airflow direction for all indoor units simultaneously.

Energy Saving Tips

Advice on maintaining unit performance and reducing energy consumption.

Maintenance and Servicing

Indoor and Outdoor Unit Cleaning

Procedures for cleaning indoor unit components and outdoor unit coils.

Troubleshooting Common Issues

Guides users on diagnosing and resolving issues like no operation or poor performance.

Troubleshooting

Noise and Airflow Diagnostics

Explains common noises and airflow issues, their causes, and solutions.

Operation and Discharge Issues

Addresses problems like dust discharge, unit not operating, or steam from the unit.

Specifications

4-Way Cassette (U1 Type) Specifications

Technical details for 4-Way Cassette indoor units, including capacity, sound levels, and dimensions.

Ceiling (T2 Type) Specifications

Technical details for Ceiling (T2 Type) indoor units, including capacity, sound levels, and dimensions.

Low Silhouette Ducted (F2 Type) Specifications

Technical details for Low Silhouette Ducted (F2 Type) indoor units, including capacity, sound levels, and dimensions.

Related product manuals