3
ENGLISH
When Connecting Refrigerant Tubing
WARNING
•
When performing piping 
work do not mix air except 
for specified refrigerant 
(R410A) in refrigeration 
cycle. It causes capacity 
down, and risk of 
explosion and injury due 
to high tension inside the 
refrigerant cycle.
•Refrigerantgasleakage
may cause fire.
•Donotaddorreplace
refrigerant other than 
specified type. It may 
cause product damage, 
burst and injury, etc.
•Ventilatetheroomwell,intheevent
that is refrigerant gas leaks during 
the installation. Be careful not to allow 
contact of the refrigerant gas with a 
flame as this will cause the generation 
of poisonous gas.
•Keepalltubingrunsasshortas
possible.
•Usetheflaremethodforconnecting
tubing.
•Applyrefrigerantlubricanttothe
matching surfaces of the flare and union 
tubes before connecting them, then 
tighten the nut with a torque wrench for 
a leak-free connection.
•Checkcarefullyforleaksbeforestarting
the test run.
•Donotleakrefrigerantwhilepipingwork
for an installation or re-installation, and 
while repairing refrigeration parts. 
Handle liquid refrigerant carefully as it 
may cause frostbite.
When Servicing
•TurnthepowerOFFatthemain 
power box (mains) before opening  
the unit to check or repair electrical 
parts and wiring.
•Keepyourfingersandclothingaway
from any moving parts.
•Cleanupthesiteafteryoufinish,
remembering to check that no metal 
scraps or bits of wiring have been left 
inside the unit being serviced.
WARNING
•Thisproductmustnotbe
modified or disassembled 
under any circumstances. 
Modified or disassembled 
unit may cause fire, 
electric shock or injury.
•Donotcleaninside
the indoor and outdoor 
units by users. Engage 
authorized dealer or 
specialist for cleaning.
•Incaseofmalfunction
of this appliance, do not 
repair by yourself. Contact 
the sales dealer or service 
dealer for repair.
CAUTION
•Donottouchtheair 
inlet or the sharp  
aluminum fins of the outdoor 
unit. You may get injured.
•Ventilateanyenclosed
areas when installing or 
testing the refrigeration 
system. Escaped refrigerant 
gas, on contact with fire 
or heat, can produce 
dangerously toxic gas.
•
Confirm after installation 
that no refrigerant gas is 
leaking. If the gas comes 
in contact with a burning 
stove, gas water heater, 
electric room heater or 
other heat source, it can 
cause the generation of 
poisonous gas.
Others
CAUTION
•Donotsitorstepon 
the unit, you may fall 
down accidentally.
•Donottouchtheair 
inlet or the sharp 
aluminum fins of the 
outdoor unit. You may get 
injured.
•Donotstickanyobject
into the FAN CASE. 
You may be injured  
and the unit may be 
damaged.
NOTICE
The  English  text  is  the  original  instructions.  Other 
languages are translations of the original instructions.
Pana_F616380_All_L.indb   3 2013-12-11   17:38:02