1-200
1
Single -Type
1-1. Unit Specifi cations
PEY1
5. Ducted Type S-100PN1E5A / U-100PEY1E8
INDOOR MODEL S-100PN1E5A
PANEL MODEL -
OUTDOOR MODEL U-100PEY1E8
Branch pipe MODEL -
PERFORMANCE TEST CONDITION ISO13253 / EN14511 / EN14825 / EN12102
POWER SUPPLY
ø, Hz 1ø 50Hz 3ø 50Hz
V 220 230 240 380 400 415 Min Max
C
O
O
L
I
N
G
CAPACITY
kW 10.0 10.0 10.0 2.7 11.5
BTU/h 34100 34100 34100 9200 39200
CURRENT A 1.54 1.48 1.42 5.45 5.20 5.05 - -
INPUT POWER
W 205 205 205 3.350k 3.350k 3.350k - -
TOTAL W - 3.555k 3.555k 3.555k 570 4.300k
ANNUAL CONSUMPTION
TOTAL kWh
*
4 - - 1778 - - -
EER/EER CLASS
TOTAL(W/W)
*
5/("A"~"G")
- - - 2.81 2.81 / C 2.81 4.74 2.67
Erp
*
6
Pdsign kW - - - - 10.0 -
SEER (W/W) - - - - 5.2 -
Annual consumption
kWh - - - - 677 -
Class - - - - A -
POWER FACTOR % - - - 94 93 92 - -
NOISE INDOOR
(H/M/L)
dB-A 44/42/37 -
Power Level dB 65/63/58 -
NOISE OUTDOOR
(H/L)
dB-A 54/-
Power Level dB 70/-
H
E
A
T
I
N
G
CAPACITY
kW 10.0 10.0 10.0 2.1 13.8
BTU/h 34100 34100 34100 7200 47100
CURRENT A 1.54 1.48 1.42 4.45 4.25 4.10 - -
INPUT POWER
W 205 205 205 2.730k 2.730k 2.730k - -
TOTAL W - 2.935k 2.935k 2.935k 450 4.100k
COP/COP CLASS
TOTAL(W/W)
*
5/("A"~"G")
- - - 3.41 3.41 / B 3.41 4.67 3.37
Erp
*
6
Pdsign kW - - - - 7.6 -
Tbivalen °C - - - - -10 -
SCOP (W/W) - - - - 3.8 -
Annual consumption
kWh - - - - 2800 -
Class - - - - A -
POWER FACTOR % - - - 93 93 93 - -
NOISE INDOOR
(H/M/L)
dB-A 44/42/37 - ⁄ ⁄
Power Level dB 65/63/58 -
NOISE OUTDOOR
(H/L)
dB-A - 54/- ⁄ ⁄
Power Level dB - 70/-
EXTRA LOW TEMP
Total CAPACITY(kW)/INPUT POWER(W)/COP
-
MAX CURRENT(A)/MAX INPUT POWER(W) 2.13/275 2.07/275 2.01/275 9.0/5.550k 9.0/5.800k 9.0/6.050k ⁄
STARTING CURRENT(A)/COMP OUTPUT(W) - - - 5.45/1.7k 5.20/1.7k 5.05/1.7k⁄
NETWORK IMPEDANCE (ΩMAX.) - -
FM OUTPUT (W) 200 90 ⁄
MOISTURE REMOVAL VOLUME L/h(Pt/h) 6.0 (12.6) -
External static pressure
Pa
50 (MIN10 ~ MAX80)
I/D AIR
FLOW
COOL m
3
/min (ft
3
/min) 36/33/26 (1271/1165/918)
HEAT m
3
/min (ft
3
/min) 36/33/26 (1271/1165/918)
O/D AIR
FLOW
COOL m
3
/min (ft
3
/min) 76 (2684)
HEAT m
3
/min (ft
3
/min) 67 (2366)
REFRIGERANT TYPE, AMOUNT
g
(oz) R410A 2.60k (91.7) /
P
R
O
D
I
M
HEIGHT : H mm(inch) 250 (9-27/32) 996 (39-7/32) /
WIDTH : W mm(inch) 1200 (+100) (47-1/4) (+3-15/16) 940 (37-1/32) /
DEPTH : D mm(inch) 650 (25-19/32) 340 (13-13/32) /
P
A
C
D
I
M
HEIGHT : H mm 338 1136 /
WIDTH : W mm 1402 1055 /
DEPTH : D mm 761 485 /
MASS
(NET) k
g
(lb) 41 (91) 73 (161) /
(GROSS) k
g
(lb) 48 (106) 81 (179) /
LAYERS LIMIT (actually) 6 (7) 2 (3)
Operation
Condition
Cool O.D(DBT) 18°C ~ 32°C -10°C ~ 43°C
Heat O.D(DBT) 16°C ~ 30°C -15°C ~ 24°C
P
I
P
I
N
G
PIPE DIAMETER mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8) (Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
CONNECT METHOD, STD LENGTH m (ft)
fl ared type, 5.0(16.4) fl ared type, 5.0(16.4)
PIPE LENGTH RANGE m (ft)
5 ~ 50 (16.4 ~ 164.0) ~ ~
I/D&O/D HEIGHT DIFFERENCE m (ft)
15 (OD located lower) / 30 (OD located higher) (49.2/98.4)
ADD GAS AMOUNT
g
/m (oz/ft)
50 (0.538)
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
30 (98.4)
*1
:
In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2
:
If the EUROVENT Certifi ed models can be operated under the “extra-low” temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3
:
Network Impedance shall be applicable for EUROPE and CHINA models.
*4
:
The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5
:
EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6
:
SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
SM830231-02Single欧州.indb200SM830231-02Single欧州.indb200 2014/09/1913:21:272014/09/1913:21:27