1-251-24
1-1. Unit Specifications
4-Way Cassette 36” × 36” (Type U2)
INDOOR MODEL S-42PU2U6
PANEL MODEL CZ-36KPU3U -
OUTDOOR MODEL U-42PE1U6
Branch pipe MODEL -
PERFORMANCE TEST CONDITION ARI Standard 210/240
POWER SUPPLY
PH, Hz 1PH, 60Hz 1PH, 60Hz
V 208 230 - 208 230 - Min Max
C
O
O
L
I
N
G
CAPACITY *1
kW 11.4 11.4 - - -
BTU/h 39000 39000 - 14000 39000
CURRENT *1 *4 A 0.80 0.76 - 25.5 23.1 - - -
INPUT POWER *1
W 100 100 - 4400 4400 - - -
TOTAL W - 4500 4500 - 950 4500
EER - - - - 8.7 8.7 - 14.7 8.7
SEER - - - - 15.6 15.6 -
POWER FACTOR % - - - 83 83 -
NOISE INDOOR
dB-A (H/M/L) 45/39/33
Power Level dB -
NOISE OUTDOOR
dB-A (H) - 53
Power Level dB - -
H
E
A
T
I
N
G
CAPACITY *2
kW 14.1 14.1 - - -
BTU/h 48000 48000 - 13500 48000
CURRENT *2 *4 A 0.78 0.73 - 24.5 22.1 - - -
INPUT POWER *2
W 100 100 - 4220 4220 - - -
TOTAL W - 4320 4320 - 870 4320
(COP) - - - - (11.1) (11.1) - 15.5 11.1
HSPF - - - - 8.9 8.9 -
(HSPF (CANADA REGIONS))
- - - - (7.4) (7.4) -
H3
2
*3
CAPACITY BTU/h - - - 27100 27100 -
(17°F)
INPUT POWER TOTAL W - - - 3310 3310 -
POWER FACTOR % - - - 83 83 -
NOISE INDOOR
dB-A (H/M/L) 45/39/33 -
Power Level dB - -
NOISE OUTDOOR
dB-A (H) - 53
Power Level dB - -
MAX CURRENT (A)/MAX INPUT POWER (W) 0.80/100 0.76/100 - 25.0/4.32k 25.0/4.77k -
NETWORK IMPEDANCE(ΩMAX.) - -
MINIMUM CIRCUIT AMPACITY (A) 15 24
MAXIMUM OVERCURRENT PROTECTION (A) 15 40
DISCONNECT SWITCH CAPACITY (A) 15 -
OUTDOOR FAN MOTOR AMPERES (A) COOL/HEAT - 1.7 / 1.7 1.6 / 1.6 -
COMPRESSOR AMPERES (A) COOL/HEAT - 14.9 / 18.0 15.0 / 18.1 -
COMPRESSOR LOCKED-ROTOR AMPERES (A) - 31.0
COMPRESSOR RATED LOAD AMPERES (A) - 18.1
OUTDOOR
DESIGN PRESSURE
HIGH SIDE MPa , psi. - (3.36) , 487
LOW SIDE MPa , psi. - (1.63) , 236
FM OUTPUT (ID/OD) W 90 90
MOISTURE REMOVAL VOLUME L/h, Pints/h 3.4, 7.1 -
Extarnal static pressure Pa, in.WC -
I/D AIR
FLOW
COOL (H/M/L) m
3
/min, ft
3
/min (CFM) 35/28/22, 1236/989/777
HEAT (H/M/L) m
3
/min, ft
3
/min (CFM) 35/28/22, 1236/989/777
O/D AIR
FLOW
COOL m
3
/min, ft
3
/min (CFM) 100, 3531
HEAT m
3
/min, ft
3
/min (CFM) 100, 3531
REFRIGERANT TYPE, AMOUNT g, lb, (oz) R410A, - R410A, 3.60k, 7.9, (127.0)
P
R
O
D
I
M
HEIGHT : H mm (inch) 319 (12-9/16) 1230 (48-7/16)
WIDTH : W mm (inch) 840 (33-5/64) 940 (37)
DEPTH : D mm (inch) 840 (33-5/64) 340 (13-3/8)
P
A
C
D
I
M
HEIGHT : H mm (inch) 361 (14-7/32) 1330 (52-3/8)
WIDTH : W mm (inch) 929 (36-37/64) 1015 (39-31/32)
DEPTH : D mm (inch) 929 (36-37/64) 409 (16-3/32)
MASS
(NET) kg (lb) 27 (60) 100 (220)
(GROSS) kg (lb) 34 (75) 109 (241)
LAYERS LIMIT ID/OD (actually) 11 (12) 2 (3)
Operation
Condition
Cool (DBT) 18°C ~ 32°C (64°F ~ 90°F) -10°C ~ 46°C (14°F ~ 115°F)
Heat (DBT) 16°C ~ 30°C (61°F ~ 86°F) -20°C ~ 24°C (-4°F ~ 75°F)
P
I
P
I
N
G
PIPE DIAMETER mm (inch)
(Liquid) ø9.52 (3/8) (Gas) ø15.88 (5/8) (Liquid) ø9.52 (3/8) (Gas) ø15.88 (5/8)
CONNECT METHOD ared type ared type
STD LENGTH m (ft) 7.6 (25)
PIPE LENGTH RANGE m (ft) 3 ~ 50 (10 ~ 165)
I/D&O/D HEIGHT DIFFERENCE m (ft) 15 (OD located lower) /30 (OD located higher) (50/100)
ADD GAS AMOUNT g/m (oz/ft) 40 (0.43)
PIPE LENGTH FOR ADDITIONAL GAS m (ft) 30 (100)
Rating conditions : Room temperature 80 °F DB / 67 °F WB (26.7°C DB / 19.4°C WB), Ambient temperature
95 °F DB / 75 °F WB (35.0°C DB / 23.9°C WB).
Rating conditions : Room temperature 70 °F DB / 60 °F WB (21.1°C DB / 15.6°C WB), Ambient temperature
47 °F DB / 43 °F WB (8.3°C DB / 6.1°C WB).
Low temp conditions : Room temperature 70 °F DB / 60 °F WB (21.1°C DB / 15.6°C WB), Ambient temperature
17 °F DB / 15 °F WB (-8.3°C DB / -9.4°C WB).
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
*1:
*2:
*3:
INDOOR CURRENT="INDOOR FAN MOTOR LOAD"
*4:
1
SM830203-04.indb 24 15/10/16 10:44:31