1-13. Capacity Table
2. Heating Capacity Performance Data
Combination of Single Unit
4-Way Cassette Type
TC :Cooling Capacity
IPT :Cooling Power Consumption
unit : kW
Outdoor air intake temp(°C W.B.)
Model
Power
Source
Ambient
Return
Air
-5°C 0°C 6°C 10°C 15°C
DB TC IPT TC IPT TC IPT TC IPT TC IPT
S-50PU1E5
U-50PE1E5
220V
230V
240V
50Hz
1 phase
16 4.6 1.79 4.9 1.84 6.7 2.19 8.3 2.62 8.8 2.51
20 4.4 1.89 4.7 1.94 6.5 2.30 8.0 2.75 8.5 2.64
24 4.3 1.94 4.5 2.00 6.2 2.37 7.7 2.84 8.2 2.72
S-60PU1E5
U-60PE1E5
220V
230V
240V
50Hz
1 phase
16 7.3 2.43 7.5 2.45 8.6 2.44 8.8 2.32 8.8 2.17
20 7.0 2.51 7.2 2.52 8.0 2.48 8.0 2.36 8.0 2.21
24 6.6 2.58 6.8 2.60 7.2 2.52 7.2 2.40 7.2 2.25
S-71PU1E5
U-71PE1E5
(U-71PE1E8)
220V
230V
240V
50Hz
1 phase
(3 phase)
16 8.2 2.88 8.5 2.90 9.7 2.86 9.9 2.67 9.9 2.47
20 7.8 2.96 8.1 2.98 9.0 2.90 9.0 2.72 9.0 2.49
24 7.4 3.05 7.7 3.07 8.1 2.96 8.1 2.78 8.1 2.55
S-100PU1E5
U-100PE1E5
(U-100PE1E8)
220V
230V
240V
50Hz
1 phase
(3 phase)
16 15.1 4.97 15.1 4.77 15.1 4.16 15.1 3.66 15.1 3.10
20 14.0 5.26 14.0 5.05 14.0 4.40 14.0 3.87 14.0 3.28
24 13.1 5.34 13.1 5.13 13.1 4.47 13.1 3.94 13.1 3.33
S-125PU1E5
U-125PE1E5
(U-125PE1E8)
220V
230V
240V
50Hz
1 phase
(3 phase)
16 16.7 5.52 17.2 5.43 17.3 4.91 17.3 4.33 17.3 3.66
20 15.5 5.84 15.9 5.74 16.0 5.20 16.0 4.58 16.0 3.87
24 14.5 5.93 14.9 5.84 15.0 5.28 15.0 4.65 15.0 3.94
S-140PU1E5
U-140PE1E5
(U-140PE1E8)
220V
230V
240V
50Hz
1 phase
(3 phase)
16 18.1 5.72 19.2 5.69 19.4 5.57 19.4 4.91 19.4 4.15
20 16.7 6.05 17.8 6.02 18.0 5.90 18.0 5.19 18.0 4.40
24 15.7 6.15 16.7 6.12 16.9 6.00 16.9 5.28 16.9 4.47