4-8
4
4-6. Automatic Flap Control
The flap position can be selected from 5 positions.
The flap will be closed automatically when the indoor unit is stopped.
Close: Types K1, T1, T2, U1, Y1
The flap closes once and moves to the set position when the operating mode is changed.
The flap for the ceiling type (T2), however, moves to the set position directly without closing when
the operating mode is changed.
4-7. Filter Sign
When accumulated operating time of the indoor unit reaches the set time, the filter sign appears on
the remote controller. Clean the filter.
Refer to “7-3. Detailed Setting Function: Simple setting items and Filter sign ON times for each model”.
After cleaning the filter, press the filter button on the remote controller once. The filter sign turns off.
Operating mode Flap position
Cooling/Dry 1 2 3
Fan 1
1
2345
Heating 2345
1
2
2
3
3
4
4
5
(Fully open)
5
1
(Fully open)
Close
Close
Except ceiling type (T2 type) For ceiling type (T2 type)
Do not change the flap position manually.
Only the swing operation can be used.
The swing operation can be set for the flap.
NOTE
SM830211-07PAC-i.indb8SM830211-07PAC-i.indb8 2013/08/0621:55:412013/08/0621:55:41