Operating Instructions
Air Conditioner
4-Way Cassette
(U1 type)
Low Silhouette Ducted
(F1 type)
Ceiling
(T2 type)
Model No.
INDOOR UNIT
4-Way Cassette
(U1 type)
S-36PU1E5A
S-45PU1E5A
S-50PU1E5A
S-60PU1E5A
S-71PU1E5A
S-100PU1E5A
S-125PU1E5A
S-140PU1E5A
Ceiling
(T2 type)
S-36PT2E5A
S-45PT2E5A
S-50PT2E5A
S-60PT2E5A
S-71PT2E5A
S-100PT2E5A
S-125PT2E5A
S-140PT2E5A
Low Silhouette Ducted
(F1 type)
S-36PF1E5A
S-45PF1E5A
S-50PF1E5A
S-60PF1E5A
S-71PF1E5A
S-100PF1E5A
S-125PF1E5A
S-140PF1E5A
OUTDOOR UNIT
Single Split
(Single-phase)
PE1 Type
U-50PE1E5
U-60PE1E5A
U-71PE1E5A
U-100PE1E5A
U-125PE1E5A
U-140PE1E5A
Single Split
(3-phase)
PE1 Type
U-71PE1E8A
U-100PE1E8A
U-125PE1E8A
U-140PE1E8A
Single Split
(Single-phase)
PEY1 Type
U-60PEY1E5
U-71PEY1E5
U-100PEY1E5
U-125PEY1E5
Single Split
(3-phase)
PEY1 Type
U-100PEY1E8
U-125PEY1E8
U-140PEY1E8
ENGLISH
2 ~ 9
Before operating the unit, read these operating instructions thoroughly and
keep them for future reference.
FRANÇAIS
10 ~ 17
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et
conservez-le pour toute référence ultérieure.
ESPAÑOL
18 ~ 25
Antes de operar la unidad, lea atentamente estas instrucciones de
funcionamiento y guárdelas para futuras consultas.
DEUTSCH
26 ~ 33
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese
Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die
künftige Verwendung auf.
ITALIANO
34 ~ 41
Prima di utilizzare l’unità, leggere a fondo queste istruzioni per l’uso e
conservarle come riferimento futuro.
NEDERLANDS
42 ~ 49
Lees deze gebruiksinstructies goed door voor u het apparaat gebruikt en
bewaar ze voor toekomstig gebruik.
PORTUGUÊS
50 ~ 57
Antes de utilizar o aparelho, leia completamente este manual de instruções
e guarde-o para futuras referências.
EΛΛΗΝΙΚΆ
58 ~ 65
Πριν θέσετε τη μονάδα σε λειτουργία, διαβάστε πολύ καλά αυτές τις οδηγίες
χρήσης και διατηρήστε τις για μελλοντική αναφορά.
БЪЛГАРСКИ
66 ~ 73
Преди да започнете експлоатация на този уред, прочетете внимателно
тези инструкции и ги запазете, за да можете да правите справки с тях и
в бъдеще.
ENGLISH
FRANÇAIS
ESPAÑOL
DEUTSCH
ITALIANO
NEDERLANDS
PORTUGUÊS
EΛΛΗΝΙΚΆ
БЪЛГАРСКИ
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
F569616
OI00F569616EU.indb1OI00F569616EU.indb1 2014/02/289:30:582014/02/289:30:58
AMP Air Conditioning
www.ampair.co.uk | sales@ampair.co.uk

Other manuals for Panasonic S-60PU1E5A

Questions and Answers:

Panasonic S-60PU1E5A Specifications

General IconGeneral
Cooling Capacity6.0 kW
Heating Capacity7.0 kW
Energy Efficiency RatingA++
RefrigerantR32
SCOP4.0
Power Supply220-240 V, 50 Hz
Energy Efficiency Ratio (Cooling)3.5
Noise Level (Outdoor)49 dB(A)
TypeSplit Type

Summary

Product Information

Safety Precautions

General Safety Warnings

Highlights critical safety warnings and cautions for safe operation and to prevent hazards.

Electrical and Operational Safety

Electrical Safety and Grounding

Guidelines for safe electrical installation, grounding, and proper cord usage to prevent fire.

User Conduct and Environmental Safety

Instructions on safe operational practices, user conduct, and environmental considerations.

Precautions for Use

Installation Requirements

Details on proper installation procedures, voltage checks, and location considerations.

Wiring and Grounding Guidelines

Instructions for conforming wiring to local codes and ensuring proper grounding.

Operation Preparation and Conditions

Steps for preparing the unit for operation and temperature range guidelines.

Names of Parts

Indoor Unit Components

Identifies parts of the U1, T2, and F1 type indoor units.

Outdoor Unit Components

Identifies parts of the PE1 and PEY1 type outdoor units.

Operation Mechanism

Heating and Defrosting Operations

Explains heating performance, defrosting cycles, and standby indicators.

DRY Operation and Power Failure Recovery

Details DRY mode operation and how the unit resumes after power interruptions.

Adjusting Airflow Direction

Vertical Airflow Control (Timer/Wireless)

Guides on adjusting vertical airflow using timer and wireless remote controllers.

Recommended Vertical Airflow Positions

Provides recommended vertical flap positions for heating and cooling modes.

Horizontal Airflow Adjustment

Instructions for manually adjusting horizontal airflow vanes on T2 type units.

Multi-Unit Airflow Control

Tips for Energy Saving

Maintenance

Indoor Unit Cleaning

Instructions for cleaning the indoor unit and air outlet flap.

Outdoor Unit Maintenance

Guidance on periodic cleaning of the outdoor unit's internal coil and components.

Before Requesting Services

Troubleshooting

Indoor Unit Issues

Addresses common noise, odor, dewdrops, fog, and airflow issues in indoor units.

Outdoor Unit Issues

Details noise and operation issues related to the outdoor unit.