: Open/Close switch
S908
: Selector switch
S911
: T. FF switch
S912
: Power switch
S913
: Rec/OTR switch
S914
: Timer Rec. switch
S915
: Power switch
S918
: Eject switch
S919
: T. Stop switch
S9001
: T. Rew switch
- The voltage value and waveforms are the reference voltage of this
unit measured by DC electronic voltmeter (high impedance) and
oscilloscope on the basis of chassis. Accordingly, there may arise
some error in voltage values and waveforms depending upon the
internal impedance of the tester or the measuring unit.
- Importance safety notice :
Components identified by mark have special characteristics
important for safety. Furthermore, special parts which have
purposes of fire-retardant (resistors), high-quality sound
(capacitors), low-noise (resistors), etc. are used. When replacing
any of components, be sure to use only manufacturer's specified
parts shown in the parts list.
Caution !
IC, LSI and VLSI are sensitive to static electricity.
Secondary trouble can be prevented by taking care during repair.
- Cover the parts boxes made of plastics with aluminium foil.