4 SPECIFICATIONS
4.1. GENERAL DESCRIPTION
Control Bus Original bus (16 bit, 8 MHz,10 megabytes per second)
Communication Bus H.100 bus conformity (1024 time slot)
Switching Non Blocking Distributed Time Switch
Power Input PSU-S
(KX-TDA0108)
100 V AC to 130 V AC/200 V AC to 240 V AC, 1.4 A/0.8 A, 50 Hz/60 Hz
PSU-M
(KX-TDA0104)
100 V AC to 130 V AC/200 V AC to 240 V AC, 2.5 A/1.4 A, 50 Hz/60 Hz
External Battery +36 V DC (+12 V DC x 3, battery capacity of 28 Ah or below recommended for 1 external
battery)
Maximum Power Failure Tolerance 300 ms (without using backup battery)
Memory Backup Duration 7 years
Dialling Trunk Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Mode Conversion DP-DTMF, DTMF-DP
Ring Frequency 20 Hz/25 Hz (selectable)
Trunk Loop Limit 1600 maximum
Operating
Environment
Temperature Cto4C
Humidity 10%to 90% (non condensing)
Conference Call Trunk From 10 x 3-party conference call to 4 x 8-party conference call
Music on Hold (MOH) 2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Paging Internal Level Control: -6 dB to +3 dB in 3 dB steps
External 2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
Serial Interface Port RS-232C 1 (max 115.2 kbps)
USB 1
Extension Connection Cable SLT 1 pair wire (T, R)
DPT 1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
APT 2-pair wire (T, R, D1, D2)
DSS Consoles and Add-on Key Module 1-pair wire (D1, D2)
Dimension KX-TDA100 334 mm (W) x 390 mm (H) x 270 mm (D)
(13 5/32 in x 15 11/32 in x 10 5/8 in)
Weight (when fully mounted) KX-TDA100 Under 12 kg (26.5 lb)
4.2. CHARACTERISTICS
Terminal Equipment Loop Limit
· PT: KX-T76xx series and KX-T7560/KX-T7565: 90 ; all other DPTs/APTs: 40
· SLT: 600 including set
· Doorphone: 20
· CS: 130
Minimum Leakage Resistance 15000 maximum
Maximum Number of Extension
Instruments per Line
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of a PT and an SLT
Ring Voltage 75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Trunk Loop Limit 1600 maximum
Hookswitch Flash/Recall Timing Range 24 ms to 2032 ms
BRI Cards Internal ISDN Mode Supply Voltage: 40 V
Power Supply: 4.5 W per 1 line,10 W per 4 lines (BRI4)
4.5 W per 1 line, 20 W per 8 lines (BRI8)
Power Supply Method: Phantom Power Supply
Door Opener Current Limit 24 V DC/30 V AC, 1 A maximum
Paging Terminal Impedance 600
MOH (Music on Hold) Terminal Impedance 10000