EasyManua.ls Logo

Panasonic TX-40DS500B - Setting Inspection; Voltage Confirmation Tests

Panasonic TX-40DS500B
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting Inspection
Voltage Confirmation
A board
Description Test point
V
oltage
PNL12V TP4097 12.1V ± 0.8V
SUB3.3V TP5400 3.32V ± 0.165V
SUB1.1V TP8100 1.2V ± 0.06V
SUB1.5V TP8101 1.52V ± 0.05V
SUB5V TP5420 5.0V ± 0.25V
HDMI3.3V TP8000 3.3V ± 0.16V
STB3.3V TP5002 3.14V - 3.46V
STB5V TP5200 4.9V - 5.4V
SUB9V TP5004 9.0V ± 0.25V
TU_1.8V TP5705 1.8V ± 0.16V
FE_1.2/1.1V TP5706 1.14V ± 0.07V
P board
Description Test point
V
oltage*
V
oltage**
24V
TP7407 and GND
<1V
24V ± 2.4V
16V TP7410 and GND
<1V
16V ± 0.6V
5VS TP7501 and 5.2V ± 0.2V 5.2V ± 0.2V
PFC TP7201 and GND TP7203***
<340V
390V ± 15V
* Connect AC 230V to JK7101 connector (Main switch is OFF).
** Connect DC 3.3V to TV_SUB_ON P2 connector – pin 9 or set main switch is ON.
*** Beware, for testing of PFC use the GND (TP7203) in Hot area of P board – risk of electric shock.
12