Overview of the MPC2000D motor protection controller.
Provides a summary of the unit's control, protection, and displayed data features.
Lists various motor starter types and circuit breakers controlled by the unit.
Categorizes protection functions into Voltage, Current, and RTD/Thermistor based.
Highlights LCD display, keypad, PC software configuration, and communication capabilities.
Details the technical data, specifications, and parameters of the MPC2000D.
Covers power supply, current, voltage, and thermistor/RTD input specifications.
Specifies time delay, range, and accuracy for thermistor and RTD inputs.
Lists rated load, operating voltage/current, and minimum permissible load for relay contacts.
Describes the various inputs the MPC2000D uses for measurement.
Details AC/DC supply options and undervoltage dip restart facility.
Covers 5-channel RTD/Thermistor inputs and their resistance ranges.
Explains the unit's control inputs and output relay assignments for motor control.
Lists the 4 output relays and their possible assignments.
Details the 17 inputs for motor starter control and status indication.
Details the functions of the unit's front panel LEDs and LCD display.
Describes the 9 LEDs providing motor starter status indications.
Describes the 2-line, 16-character LCD for settings and data.
Explains the operation of the functional keypad and LCD display.
Explains how to navigate through setting parameter pages.
Explains how to navigate through displayable data pages.
Overview of the unit's setting and data pages for configuration.
Details Drive Number, Baud Rate, and Serial Link Number settings.
Details settings for start times, undercurrent, overload, and thermal capacity.
Configures how protective functions trigger trips, alarms, and resets.
Explains internal test routines and watchdog functions for maintenance.
Checks monitored hardware and software routines for errors.
Provides procedures for diagnosing and rectifying common faults and operational issues.
Details the thermal overload protection curves and operating principles.
Explains how the MPC2000D simulates motor thermal condition.
Guides on the physical installation and mounting of the MPC2000D unit.
Details the drawout case for flush mounting on starter/cubicle fronts.
Describes screw and blade type connectors for the rear terminal block.
Details different methods for starting motors and controlling circuit breakers.
Method for starting a motor in one direction using Contactor A.
Method using Contactor A & B and extra variables for Star to Delta transition.
Method for controlling circuit breakers using output relays.