Double "Stay" Arming
During the “stay” arming exit delay, pressing [STAY] (key [11]) again will switch any delay 1 or delay 2
zones to instant zones. (24 hour "stay" zones, follow "stay" zones, and instant "stay" zones are not
affected.) Full system arming cancels "double stay" arming.
Fast Exit
Exit while the system is armed in "stay" mode (key [11/STAY] is flashing):
A: Fast exit and Stay key [11]
To exit the premises and remain "stay armed": press key [11/STAY] for two seconds. The system switches
to "exit delay" mode ("ready" LED flashes). At the end of the "exit delay" period, the system will return to
"stay" arming mode.
B: Fast exit and Regular Arm key [10]
To exit the premises and "regular" arm: press key [10] for two seconds. The system switches to "regular"
arming (key [11] and [12] are flashing) with "exit delay" ("ready" LED flashes). At the end of the "exit
delay" period, the system is "regular" armed.
System Disarming
The protected area should be entered through a designated entry/exit door. The keypad sounder will
beep to remind user to disarm the system. A valid access code should be entered on the keypad, before
the allotted entry time expires. If the access code is entered incorrectly, press [CLEAR] and re-enter it. The
"armed" light will extinguish and the sounder will change to the "CONF" beep (series of short beeps)
before silencing.
Alarm Memory
The memory light [MEM] on your keypad will illuminate if any alarm situations took place while your sys-
tem was armed. A record of all alarm situations that occurred is stored in memory. After disarming the
system, pressing once on the [MEM] key causes it to flash and brings up, in the keypad display, the alarm
events that occured during the last alarm period. (Alarm events consist of all zones that generated
alarms.)
SYSTEM PARTITIONING
By activating the panel's "partitioning" feature, zones can be divided into two distinct systems, with a
shared fire zone (zone #3). Both systems are controlled by one panel, making partitioning a particularly
useful feature in installations where shared security systems are more practical (i.e. office/warehouse,
apartment/condo complexes).
Partitioning
Partition "on" (Address 206, key [8] "on")
Addresses 240 and 242:
Zones can be assigned to system “A” (address 240, zone key “ON”) and/or to system “B” (address 242, zone
key “ON”). A “common zone” is a zone that is not assigned to any system (it will be reported as a “System A”
zone). It is armed only when both systems are armed, and disarmed if system “A” or system “B” is disarmed.
A “dual zone” is a zone that is assigned to both systems (it will be reported as a “System B” zone). It is
armed if either system “A” or system “B” is armed, and disarmed only when both systems are disarmed.
Note: When partitioning is not activated (address 206, key [8] "off") any zones selected at address
240 will be armed upon "stay" arming.
Keypad display:
Both systems are displayed on the keypad at the same time. In partitioning mode, when System "A" is
armed, the [STAY] key illuminates. If System "B" is armed, the [AWAY] key illuminates. If both systems are
armed, both of these keys will illuminate.
IM28-38EX