Esprit 728 Ultra & 738 Ultra - 1 - Programming Guide
System Programming Guide
Software Versions 5.0 (728ULT) and 5.0 (738ULT)
Installer Code (default - 728 Ultra: 282828; 738 Ultra: 383838)
Full access to programming, except user access codes (PINs). No access to arming/disarming. Use only numeric keys from [0] to [9].
Zone Recognition
Streamlined Section Programming
This is an alternate method to Hex Programming (see page 2). Addresses 000 to 043 and 300 to 527 are grouped into 68 sections where
each section contains four addresses (i.e. section 00 = addresses 000 to 003). Using this method allows you to program 8 digits
(4 addresses) without having to exit and re-enter addresses.
The keypad will not display the current data in the Streamlined Section Programming method.
Table 1: Zone Recognition
Device connected to which input? 728 Ultra
No ATZ
728 Ultra
With ATZ
738 Ultra
No ATZ
738 Ultra
With ATZ
Control Panel
Input 1 = Zone 1 Zones 1 & 2 Zone 1 Zones 1 & 9
Input 2 = Zone 2 Zones 3 & 4 Zone 2 Zones 2 & 10
Input 3 = Zone 3 Zones 5 & 6 Zone 3 Zones 3 & 11
Input 4 = Zone 4 Zones 7 & 8 Zone 4 Zones 4 & 12
Input 5 = N/A N/A Zone 5 Zones 5 & 13
Input 6 = N/A N/A Zone 6 Zones 6 & 14
Input 7 = N/A N/A Zone 7 Zones 7 & 15
Input 8 = N/A N/A Zone 8 Zones 8 & 16
Keypad
Zone 1 = Zone 5 Zone 9 Zone 9 Zone 17
Zone 2 = Zone 6 Zone 10 Zone 10 Zone 18
Table 2: Streamlined Section Programming Method
1. Press [
ENTER] + [INSTALLER CODE] (default - 728 Ultra: 282828; 738 Ultra: 383838) + [7].
2. The [
ENTER] and [2ND] keys will flash to indicate you are in programming mode (LED keypad only).
3. Enter 2-digit [
SECTION] (00 to 67).
4. The [ENTER] key will remain on while the [2ND] key will be off (LED keypad only).
5. Enter 8-digit [
DATA] to program the section.
6. The keypad will beep to indicate that the section has been programmed, data is saved and the
software has advanced to the next section.
7. Return to step 4 or press [
CLEAR] to exit programming mode.
&
Question and Answer IconNeed help?

Do you have a question about the Paradox Esprit 738 Ultra and is the answer not in the manual?

Paradox Esprit 738 Ultra Specifications

General IconGeneral
BrandParadox
ModelEsprit 738 Ultra
CategoryControl Panel
LanguageEnglish

Summary

Zone Recognition

Streamlined Section Programming

Streamlined Section Programming Method

Alternate programming method using sections for efficient data entry without exiting and re-entering addresses.

Hex Programming

Hex Programming Method

Alternate method using hexadecimal digits from 0 to F for programming data entry.

Installer Panel Answer Options

Telephone and Account Numbers

Reporting Codes

Arming (Closing) Report Codes

Disarming (Opening) Report Codes

Report Code Definitions

Decimal Programming

Feature Select Programming

Zone Definition

Key Access Programming

Connection Diagrams

Advanced Technology Zone (ATZ) Connections

Other Connection Diagrams

Detector Wiring and Connections

728 Ultra Wiring Diagram

738 Ultra Wiring Diagram

Power Down Reset

Related product manuals