Esprit 728 Ultra & 738 Ultra - 3 - Programming Guide
Installer / Panel Answer Options
Telephone and Account Numbers
If only one monitoring station telephone number is used, program the same number for telephone numbers 1 and 2. If only one account
number is required, the same number must be entered for both accounts "A" and "B".
[0] to [9] = numeric value [
BYP] = switch from pulse to tone while dialing
[
STAY] = * [MEM] = pause 4 seconds
[AWAY]/[FORCE] = # [TBL]/[TRBL] = end of number
Streamline Section Data
Description
Address Answering Machine Override
___ / ___ Installer code (1st, 2nd digit) 000
[2ND] or [1] = disabled [5] = 40 seconds
___ / ___ Installer code (3rd, 4th digit) 001
[2] = 16 seconds [6] = 48 seconds
___ / ___ Installer code (5th, 6th digit) 002
[3] = 24 seconds [7] = 56 seconds
___ / ___ Panel answer options
003
[4] = 32 seconds [8] to [F] = 60 seconds
Number of rings (Max. 15)
Streamline Section Data
Description
Address
___ / ___ Panel Identifier (1st, 2nd digit) 004
___ / ___ Panel Identifier (3rd, 4th digit)
005
___ / ___ PC Password (1st, 2nd digit) 006
___ / ___ PC Password (3rd, 4th digit)
007
Computer Telephone Number
(View at addresses
008
to
015
)
Streamline Section Streamline Section
Press the [TBL]/[TRBL]
key to end phone
number if less than 16
digits are programmed.
02
__/__/__/__/__/__/__/__
03
__/__/__/__/__/__/__/__
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Monitoring Station Telephone Number 1
(View at addresses
016
to
023
)
Streamline Section Streamline Section
Press the [TBL]/[TRBL]
key to end phone
number if less than 16
digits are programmed.
04
__/__/__/__/__/__/__/__
05
__/__/__/__/__/__/__/__
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Monitoring Station Telephone Number 2
(View at addresses
024
to
031
)
Streamline Section Streamline Section
Press the [TBL]/[TRBL]
key to end phone
number if less than 16
digits are programmed.
06
__/__/__/__/__/__/__/__
07
__/__/__/__/__/__/__/__
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Accounts “A” and “B” (View at addresses 032 to 035)
Streamline Section
For 3-digit account
numbers, enter “skip”
([2
ND]) as first digit.
The Standard Pulse
report format can
support 3- or 4-digit
account numbers.
The Ademco Express,
Ademco Contact ID
and the Pager report
formats only support 4-
digit account numbers.
08
__/__/__/__ __/__/__/__
1234 5678
AB
{
Identifies the control panel to the PC.
{
Identifies the PC to the control panel.
First digit disables Answering Machine Override (key
[2
ND] or key [1]), or determines period of time
between first and second call. Second digit
determines number of rings required before panel
will answer. If [2
ND][2ND] is entered, panel will not
answer (default value is [2
ND] [8]).