StayD Installer Setup Guide
MG5000 V2.0
*For new unprogrammed panels or reset panels*
Step A: Define the zones
Set up your zones as you would normally and define which zones are disabled during Stay or Sleep arming.
See the Zone Definitions table in the MG5000 Programming Guide on page 9.
Step B: Assign entry point zones to keypads
1 Go to each keypad that requires entry point zone assignment.
2 [
ENTER] + [INSTALLER CODE] (default: 0000 / 000000).
3 Press and hold the [
OFF] key for three seconds.
4 Enter the desired zone number(s):
MG32LED / MG32LRF = 2-digit entry 01 to 32
MG10LEDV/H = 1-digit entry 1 to 0(10)
The first zone you program will be the designated entry point and will flash. Up to three more path zones can
be added; these zones will light up and stay lit.
5 Press [
ENTER] to save and exit.
Step C: Activate StayD mode
1 Go to any keypad.
2 [
STAY] + [USER CODE] + (If partitioned, press 1 and/or 2) + [STAY].
3 The StayD LED will light up to confirm StayD activation.
Congratulations, your system is now StayD enabled and ready.
Question and Answer IconNeed help?

Do you have a question about the Paradox STAY D MG5000 and is the answer not in the manual?

Paradox STAY D MG5000 Specifications

General IconGeneral
CategorySecurity System
ManufacturerParadox
StayD ModeYes
CommunicationSupports GSM
ExpandableYes
Battery BackupYes, with rechargeable battery

Summary

Define the Zones

Assign Entry Point Zones to Keypads

Keypad Entry Point Zone Assignment

Procedure for assigning entry point zones to keypads, including zone number entry (01-32 or 1-10).

Activate StayD Mode

StayD Mode Activation

Steps to activate StayD mode using a keypad and confirming activation with the StayD LED.

StayD Advanced Settings

Flex-Instant Zones

Configuration for Flex-Instant zones, defining delay for zones during Stay or Sleep arming.

Re-arm Delay

Setting the delay period before a zone automatically re-arms after activation.

EntryExit Paths Explained

Path Zone Programming

Details on programming path zones, entry points, and validation for keypad or remote entry/exit.

EntryExit with Keypad

How path zones function during entry and exit when using a keypad for system interaction.

EntryExit with Remote Control

Using a remote control to disarm, defining paths, and re-arming the system automatically.

Window Mode and Re-arm Delay

Using Window mode to open one zone during Stay arming and managing re-arm delays.

Related product manuals