P a g e | 40
P10 MAINTENANCE INSTRUCTIONS
Replacement Handset
Follow the guide stipulated on page 6 of the users instructions “Changing the handset batteries
to load the batteries into the new handset.
Re-Pairing the handset or ECU unit
When replacement handset or ECU the two items will need to be re-paired using the following
procedure.
Start the pairing process with the power to the appliance turned off.
Make sure that the remote handset has batteries installed then turn the power on to the
appliance on.
Within 30 seconds of power on, press any button on the remote handset.
The LED on the handset will start to flash quickly indicating the pairing process has started. If
successful pairing is achieved then the LED will show 5 slow flashes. If pairing fails there will be 3
long flashes.
If this happens then remove power to the appliance and repeat the pairing process.
Short Spares List
Component
Part No
Burner Assembly
Injector (Mrk 770)
7815
ODS Unit (oxy Pilot 2900)
7280
Control Valve
6590
Electrical Control Unit (ECU)
8080
Ignition Lead
6646
Handset
8081
P10 Fuel Bed
8462