43
3. 2
nd
or 3
rd
stage piston stuck
3.Replace
4. Blocked Sintered Filter of 2
nd
stage
separator (when 1
st
stage safety valve
opens)*
4.Clean or Replace
5. Blocked Sintered Filter of 3
rd
final
stage separator (when 2
nd
stage safety
valve opens)*
5.Clean or Replace
Compressor runs too
hot
1.Insufficient supply of fresh cooling air
1. Check location. Max Ambient
temperature under 40 ºC
2.Intake or outlet valves are not closing
properly
2.Check and clean valves, Replace if
necessary
3.Wrong direction of rotation
3.See arrow on the compressor and
remedy accordingly
4.Low oil level
4.Check oil level
Oil residue/Oil smell in
delivered air
1.Improper maintenance of final filter
1.Service filter - Renew BA cartridge
2.Wrong type of oil
2.Use right type of oil
3.Activated carbon saturated
3.Renew BA cartridge
4.1
st
, 2
nd
, or 3
rd
stage piston rings worn
4. Check - Replace
5. Worn Cylinders
5. Check - Replace
* Concerns only compressors equipped with separators part numbers 208501600, 208501610, 208501620 &
208704200.