User Manual - Cyclone Silent - 1-2018 edition
PARAMINA SA – Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1
Fax: 0030 210 5575868, email: service@paramina.gr - website: www.paramina-compressors.com
1
USER MANUAL
CYCLONE
SILENT

Table of Contents

Questions and Answers

  • S
    Samuel GuerreroAug 13, 2025
    Why does my Paramina Air Compressor run too hot?
    • L
      Laura FriedmanAug 13, 2025
      If your Paramina Air Compressor runs too hot, there are several potential causes. First, ensure there is sufficient fresh cooling air supply by checking the location and inlet air suction, maintaining an ambient temperature under 45 ºC. Also, check and clean the intake or outlet valves, replacing them if necessary. Verify the compressor's rotation direction against the arrow and correct it if wrong. Finally, check the oil level and replenish if low.
  • A
    Amanda MitchellAug 17, 2025
    Why has the performance of my Paramina Air Compressor decreased?
    • H
      Haley MartinezAug 17, 2025
      If your Paramina Air Compressor's performance has decreased, consider these potential causes: a blocked air intake filter (clean or replace it), valves not properly closed (check the intermediate pressures), worn piston rings or cylinders (replace them), leaking pipes (tighten and reseal), solenoid valves stuck open (clean or replace them), or an unstable power supply (check the power supply fuse box).
  • Z
    zfloresAug 21, 2025
    What causes the main motor protection to activate on a Paramina Air Compressor?
    • M
      Mr. Robert ReeseAug 21, 2025
      If the main motor protection has activated on your Paramina Air Compressor, it could be due to an unstable power supply, so check and stabilize it. Another cause may be high power consumption due to motor faulty wiring, motor overload via bearings, compressor block overload or high inlet pressure.
  • D
    Diane WhiteAug 25, 2025
    Why does my Paramina Air Compressor not attain final pressure?
    • K
      Kimberly HowardAug 25, 2025
      If your Paramina Air Compressor is not attaining final pressure, there might be a leak in the condensate drain valve or fittings, so tighten and reseal them. Other potential causes include premature opening of the final safety valve (clean and readjust), excessive piston clearance (replace and regulate again), the final safety valve’s safety lock opening prematurely (check the intermediate pressures, regulate or replace valves), leaking interstage safety valves (check or replace), or worn final stage piston rings (check or replace).
  • C
    camposjohnAug 28, 2025
    Why is there oil residue/oil smell in the air delivered by my Paramina Air Compressor?
    • H
      hlandryAug 28, 2025
      If you notice oil residue or smell oil in the air delivered by your Paramina Air Compressor, consider these factors: improper maintenance of the final filter (service the filter and renew the BA cartridge), using the wrong type of oil (use the right type of oil), saturated activated carbon (renew the BA cartridge), or worn piston rings or cylinders (check and replace if necessary).
  • L
    Lauren TrevinoSep 1, 2025
    What causes the motor to start with difficulty in my Paramina Air Compressor?
    • J
      Jon BrownSep 1, 2025
      If your Paramina Air Compressor motor starts with difficulty, first check and stabilize the power supply to address any instability. Also, pressure may remain in the stages because of too short time between stop – start, so check drains function. High inlet pressure may be the reason, so check inlet valve and inlet pressure regulator setting. Finally, check star/delta function because star-delta switching may be incorrect.
  • S
    Sean ThorntonSep 5, 2025
    What causes safety valves between individual stages to release pressure in my Paramina Air Compressor?
    • R
      Rhonda ThomasSep 5, 2025
      If the safety valves between individual stages of your Paramina Air Compressor are releasing pressure, several issues could be the cause. If the 1st stage safety valve is released, the 2nd stage valves may not be closing properly, so check and replace the valves. Similarly, if the 2nd stage safety is released, the 3rd stage valves may not be closing properly, so check and replace the valves. Other causes may be stacked 4th stage piston (replace it), blocked Sintered Filter of 3rd stage separator (when 2nd stage safety valve opens, so clean or replace the filter), blocked Sintered Filter of 4th – final stage separator (when 3rd stage safety valve opens, so clean or replace the filter).
  • M
    Matthew HuntSep 9, 2025
    What should I do if my Paramina Air Compressor has the wrong rotation direction?
    • J
      Jonathan HodgesSep 9, 2025
      If your Paramina Air Compressor has the wrong rotation direction, it is likely that the phases are reversed. To correct this, change the phases.

Summary

General Instructions

User Instructions

Safety Measures and Recommendations

Explains warning signs, basic safety recommendations, and operational risks.

Safety Regulations and Special Attention

Covers safety regulations and specific attention points for operation.

Installation and Operation

General Specifications and Installation

Details general specifications and the first start procedure for the compressor.

Operation Procedures

Covers ventilation, transport, cylinder filling, auto start/stop, and condensate drainage.

Electronic Controller

Controller Operation Modes

Explains semi-automatic and fully automatic operating modes.

Display and Navigation

Details the display unit, keypad, LEDs, symbols, and menu navigation.

Controller Menus and Parameters

Covers User Menu (POO), Operation Menu (P01), and log/shutdown/alarm menus.

Fault Messages and Codes

Explanation of fault messages, types, codes, and their meanings.

Error Log, Shutdowns, and Alarms

Details immediate/controlled shutdowns, alarms, start inhibits, and service alarms.

Maintenance

Compressor Storage and Re-operation

Guidelines for long-term storage and re-operation of the compressor.

Intake Air Filter and Belt Adjustment

Procedures for replacing the intake air filter and adjusting the compressor belt.

Oil Change and Filter Maintenance

Covers oil change and detailed filter maintenance procedures.

General Service and Torque Values

General service instructions, torque values, and maintenance calendar.

Trouble Shooting

Guide to diagnosing and resolving common compressor problems.

Spare Parts Catalog

Technical Diagrams

P & I Diagram

Piping and instrumentation diagram of the compressor system.

Cooling air - Dimensional Diagram

Dimensional drawing showing cooling air flow and layout.

Certificates

Paramina CYCLONE SILENT 24E Specifications

General IconGeneral
Power1.5 HP
Voltage230 V
Frequency50 Hz
Tank capacity24 l
Max. pressure8 bar
Weight22 kg
TypeOil-free