10-Bolt Powershift P.T.O.s
Direct Mount Pump Support Recommendations
Chelsea strongly recommends the use of pump supports (Support Brackets) in all applications.
P.T.O. warranty will be void if a pump bracket is not used when:
1) The combined weight of pump, fittings and hose exceed 40 pounds [18.14 kg].
2) The combined length of the P.T.O. and pump is 18 inches [45.72 cm] or more from the P.T.O.
centerline to the end of the pump.
ALSO: Remember to pack the female pilot of the P.T.O. pump shaft with grease before
installing the pump on the P.T.O. (reference Chelsea grease pack 379688)
Use caution to ensure that bracket does not pre-load pump/P.T.O. mounting
NOTE: For Proper Bracketing Attach at 2 or More
Transmission Bolt Locations and 2 or More
Pump Locations. Contact Transmission
Manufacture for Proper Bracket Mounting
Locations.