Description
EN
5
Minimum Operating Pressure
4 bar g
58 psi g
Maximum Operating Pressure DME012 - DME040
16 bar g
232 psi g
Maximum Operating Pressure DME050 - DME080
13 bar g
190 psi g
Minimum Operating Temperature
5
o
C
41
o
F
Maximum Inlet Air Temperature
50
o
C
122
o
F
Maximum Ambient Air Temperature
55
o
C
131
o
F
Noise Level <75 dB(A)
Standard Electrical Supply 230 V 1ph 50 Hz
Optional Electrical Supply 110 V 1ph 60 Hz
Nominal Dewpoint
-40
o
C
-40
o
F
Optional Dewpoint
-70
o
C
-100
o
F
Nominal ISO 8573.1 : 2010 Classification Class 2 Water
Optional ISO 8573.1 : 2010 Classification Class 1 Water
Standard Thread Connections BSPP
Optional Thread Connections NPT
Approvals
CRN
OH0373.9C (DME012 - DME040)
OH0372.9C (DME050 - DME080)
CSA-US 173682 (LR56310)
Before continuing with the installation and commissioning of this equipment:
Ensure that it is correctly sized for the inlet pressure, taking into consideration the pressure drop caused by the valves, pipes and filters within
the system. Allowance should be made for purge air loss. The dryer should be typically sized at 1 bar (14 psi/0.1MPa) below nominal
compressor output pressure.
The purge air flow is factory set for 6 bar g (87 psi g) minimum system pressure. Should the minimum supply pressure be higher or lower than
this figure the purge air flow must be reset in order to maintain the specified dewpoint. Please contact your local Parker domnick hunter office
for assistance.
Ensure that it is correctly sized for inlet temperature to meet the dewpoint specified.
-40°C (-40°F) or -70°C (-100°F).
Ensure that the electrical supply voltage and frequency meet the requirements detailed within this specification and on the equipment rating
plate.