EasyManua.ls Logo

Parker DME012-RX - User Manual

Parker DME012-RX
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Medical Air Dryer
DME012-RX - DME080-RX
Original Language
User Guide
aerospace
climate control
electromechanical
filtration
fluid & gas handling
hydraulics
pneumatics
process control
sealing & shielding
EN

Questions and Answers

  • D
    Dr. Tommy EdwardsAug 9, 2025
    What to do if my Parker DME012-RX Dehumidifier has a high differential pressure?
    • M
      Mathew FarleyAug 9, 2025
      If your Parker Dehumidifier shows a high differential pressure, the cause might be excessive outlet flow. Check and regulate the air demand to resolve this issue.
  • B
    Brian AdamsAug 14, 2025
    Why is my Parker DME012-RX's outlet air flow stopping?
    • L
      Lisa HollandAug 14, 2025
      If the outlet air flow of your Parker Dehumidifier stops, this could be due to an electrical fault or a blown fuse in the plug. In such cases, contact customer services.
  • J
    Joshua PorterAug 19, 2025
    How to troubleshoot poor dewpoint in Parker DME012-RX?
    • S
      Stephanie ThompsonAug 19, 2025
      If your Parker Dehumidifier has a poor dewpoint, several factors could be responsible: * Entrained water. * Excessive airflow demand. * Inlet pressure too low. * Excessive inlet air temperature. * Insufficient purge airflow. * Blocked exhaust silencers. * Contaminated desiccant. To address these issues: * Check pre-filtration drains. * Compare the actual flow against the dryer's rated flow. * Check for recent additions to the air system. * Check against the technical specification. * Ensure the system pressure is at the factory setting of 6 bar g (87 psig). * Eliminate the source of contamination.
  • L
    Lori FisherAug 25, 2025
    What to do if Parker DME012-RX Dehumidifier constantly depressurizes?
    • M
      Mike KennedyAug 25, 2025
      If your Parker Dehumidifier is constantly depressurizing, the cause might be a damaged valve. In such cases, contact customer services.
  • G
    Gregory MendezAug 29, 2025
    Why is my Parker Dehumidifier failing to purge?
    • D
      David CabreraAug 29, 2025
      If your Parker Dehumidifier is failing to purge, it could be due to a blocked or shut purge valve or blocked exhaust silencers. In such cases, contact customer services.
  • P
    phillipmorganSep 3, 2025
    How to fix an electrical fault in Parker DME012-RX Dehumidifier?
    • B
      Brandon PotterSep 3, 2025
      If your Parker Dehumidifier has an electrical fault, this could be due to a hardware fault. In such cases, contact customer services.

Parker DME012-RX Specifications

General IconGeneral
CategoryDehumidifier
ModelDME012-RX
Capacity12 liters/day
Power Supply220-240V, 50Hz
Power Consumption210W
Water Removal TechnologyCompressor
Weight11 kg
Operating Temperature5°C to 35°C