Technical Specification
Seasoned Wood (less than 20% moisture content)
Mean Flue Gas Temperature
Flue Outlet Size (Top or Rear Option)
- Where leakage is greater than
5m³/hour/m²
- Ventilation normally required =
550mm² per kW output over 5kW
- Where leakage is less than or equal
to 5m³/hour/m²
- Ventilation normally required =
550mm² per kW output
For further information on ventilation please refer to Building Regulations Document J or your installer.
SMOKE CONTROL AREAS - This stove has been designed and assembled so that it may be used to burn wood logs in a
Smoke Control Area. Find out if you are in a Smoke Control Area by contacting your Local Authority. These appliances
are only exempt for use when fitted with a smoke control kit (ECIC04ARRT020 – Aspect 4’s/ECIC05ARRT020 – Aspect
5’s) (ECIR05ARRT020 – Aspect 6. Without the kit fitted the appliance is not an exempt appliance and so may leave the
householder liable for a fine up to £1000.