EasyManua.ls Logo

Parkside PKS 1500 A2 - User Manual

Parkside PKS 1500 A2
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
IAN 290768
MITRE SAW PKS 1500 A2
HU SI
CZ SK
FEJE- ÉS GÉRVÁGÓ FŰRÉSZ
Kezelési és biztonsági útmutató
Az eredeti használati útmutató fordítása
HU
ČELILNA IN ZAJERALNA ŽAGA
Napotki za upravljanje in varnost
Prevod originalnih navodil za uporabo
SI
POKOSOVÁ PILA
Pokyny k obsluze a bezpnostní pokyny
Překlad originálho návodu k obsluze
CZ
SKRACOVACIA A POKOSOVÁ PÍLA
Upozornenia k obsluhe a bezpečnostné upozornenia
Preklad origilu návodu na obsluhu
SK CHAT
KAPP- UND GEHRUNGSSÄGE
Bedienungs- und Sicherheitshinweise
Originalbetriebsanleitung
DE
MITRE SAW
Operating and Safety Instructions
Translation of Original Operating Manual
GB

Table of Contents

Other manuals for Parkside PKS 1500 A2

Questions and Answers

  • F
    Frank EdwardsJul 25, 2025
    Why does my Parkside PKS 1500 A2 Saw motor overheat easily?
    • D
      Dennis SinghJul 26, 2025
      Your Parkside Saw motor may overheat because it is being overloaded or not sufficiently cooled. To resolve this, avoid overloading the motor during cutting. Additionally, remove any dust from the motor to ensure it cools effectively.
  • D
    Daniel PattersonJul 30, 2025
    What to do if my Parkside Saw motor does not work?
    • V
      vhallJul 30, 2025
      If the motor of your Parkside Saw doesn't work, the cause may be a defective motor, cable, or plug, or burnt fuses. Check the fuses and replace them if necessary. It is recommended to arrange for a specialist to inspect the machine. Never attempt to repair the motor yourself due to the danger.
  • H
    Howard MartinezAug 2, 2025
    Why doesn't my Parkside Saw motor reach its full power?
    • B
      Brian FernandezAug 2, 2025
      The motor in your Parkside Saw might not reach its full power because the circuits in the network are overloaded by other equipment like lamps or other motors. To fix this, avoid using other equipment or motors on the same circuit.
  • R
    Randall SerranoAug 7, 2025
    How to fix a rough or wavy saw cut with my Parkside Saw?
    • S
      Stacy RiceAug 7, 2025
      A rough or wavy saw cut from your Parkside Saw is likely due to a dull saw blade or a tooth shape that isn't appropriate for the material thickness. To correct this, resharpen the saw blade or use a suitable blade for the material you're cutting.
  • T
    Tracey ChanAug 11, 2025
    Why does my Parkside Saw motor start slowly and not reach full speed?
    • L
      Leah WilliamsAug 11, 2025
      If your Parkside Saw motor starts slowly and doesn't reach its operating speed, it could be due to low voltage, damaged coils, or a burnt capacitor. Contact the utility provider to check the voltage. It's also recommended to arrange for a specialist to inspect the motor and replace the capacitor.
  • T
    Thomas GrimesAug 15, 2025
    What to do if the workpiece pulls away or splinters when using my Parkside Saw?
    • C
      Charles ShannonAug 15, 2025
      If the workpiece pulls away or splinters when using your Parkside Saw, it may be due to excessive cutting pressure or an unsuitable saw blade. Try inserting a suitable saw blade.
  • M
    Mr. Adam ColeAug 20, 2025
    Why is my Parkside Saw motor making excessive noise?
    • S
      susanhughesAug 20, 2025
      If your Parkside Saw motor is making excessive noise, the cause might be damaged coils or a defective motor. It is recommended to arrange for a specialist to inspect the motor.

Summary

Introduction and Specifications

Scope of Delivery

Lists items included with the mitre saw, such as dust bag, workpiece clamp, tools, and accessories.

Technical Data

Provides specifications like dimensions, weight, speed, power, and cutting capacity of the mitre saw.

Important Information

Information about Noise Development

Details the noise levels (LpA, LA) and advises on hearing protection if noise exceeds 85 dB(A).

Safe Work Practices

Outlines general safety precautions for using electric tools, like keeping the area tidy and protecting against electric shock.

Proper Use

Intended Use and Warnings

Explains the mitre saw's intended use for wood/plastic and warns against misuse or using incorrect blades.

Additional Safety Instructions

Protective Equipment and Dust Extraction

Emphasizes protective gear, dust extraction, and safe handling of blades and components.

Maintenance and Repair

Safe Maintenance Practices

Covers safe practices for maintenance, including unplugging the tool and securing parts.

Saw Blade Handling

Provides instructions on using insertion tools, observing speed limits, and proper blade mounting.

Assembly and Commissioning

Assembly Steps

Guides on unpacking and assembling the mitre saw, including dust bag and workpiece clamp.

Moving and Positioning

Details how to move the saw and set up the work station for stable and safe operation.

Working Instructions

Settings and Adjustments

Explains how to pivot the table plate and tilt the saw unit to desired angles using scales.

Cutting Procedures

Details cross-cutting, mitre cuts, and double mitre cuts, including workpiece fixing and saw operation.

Electrical Connection

Cable Safety and Motor Details

Warns about damaged cables, explains AC motor specifics, and mentions motor overload protection.

Maintenance and Disposal

Service Tasks and Decommissioning

Covers routine service tasks, decommissioning, and environmentally friendly disposal of the machine.

Troubleshooting

Fault Identification and Remedies

Lists common faults, their possible causes, and remedies for the mitre saw.

Guarantee Certificate

Guarantee Terms and Conditions

Explains the terms and conditions for guarantee claims, coverage, and exclusions.

Declaration of Conformity

EU Directives and Standards Compliance

Lists the EU directives and standards the product complies with, including safety and emission standards.

Parkside PKS 1500 A2 Specifications

General IconGeneral
Power1500 W
No-load speed5000 rpm
Blade diameter190 mm
Bore diameter30 mm
Cutting depth at 45°0 - 45 mm

Related product manuals