- 12 -
Press key " " for 5 seconds, and enter into the unit status parameter inquiry,
press key " , " to view the parameters, press key " "to exit parameter
query.
Inquiry Code
Descriptions
Display Range
01
Inlet water temp
-20~99
02
Outlet water temp
-20~99
03
Ambient temp
-20~99
04
Discharge temp
0~125
05
Suction temp
-20~99
06
Outer coil temp
-20~99
07
Inner coil temp
-20~99
08
Main EEV steps
09
Assistant EEV steps
/
10(A)
Compressor current
11(B)
Radiator temp
12(C)
DC bus voltage
13(D)
Compressor actual rotate speed
14(E)
DC fan motor actual rotate speed
8) Starting Electric Heater Manually
Press keys " " + " " at the same time for 5 seconds to turn on/off the
electric heater manually.
9) Enforced Defrosting
When the conditions of entering enforced defrosting are met, press" "and" "at
the same time for 5 seconds, then it enter into enforced defrosting mode.
When entering into defrosting, heating mode icon" "appears. When
exiting from defrosting, mode icon recover to normal display.
10) Recover to Factory Default
By button operation: press keys" "+" "at the same time for 5 seconds
and enter into user parameters mode, the current parameter is return temperature.
Then press keys" "+" "at the same time for 5 seconds and wired
controller recovers to factory default. At this time, buzzer will alarm twice
continuously, and all parameters recover to factory default.