12
6. Attach the other end of the high pressure hose to high pressure outlet ("A" on diagram below) on pump.
Pull down on collar of quick-connect, slide onto pump and let go of collar. Note that some pumps require
the hose to be threaded on. Tug on the hose to ensure connection is secure.
7. Turn water supply on if you have not already done so. Point the gun in a safe direction and squeeze the
trigger to purge the pump of air and debris. Do this until water ow is owing at a steady rate. Continue
to hold trigger of gun down while starting the machine to ensure there is no pressure build-up.
8. Take a nal look at all connections to make sure there are no leaks or loose connections. If there are any
leaks in hoses, they must be replaced.
IMPORTANT: DO NOT siphon standing water for the water supply.
Make sure burner switch is OFF
9. To start the machine, locate the electric ignition switch on the right side of the engine. Insert the key and
turn it to the "ON" position" until the unit starts. Do not hold the switch to the "ON" position for more than
5 seconds as this can cause damage to the engine. Check to ensure fuel valve is in the ON position
and if starting cold, move the choke lever to the "CLOSED" position. Reference the component diagram
below for the location of these parts.
Regardless of the starting method, remember to gradually move the choke lever back to the "open"
position once the engine is running.
*Pump Uses SAE30
Non-Detergent Mineral Oil
A
*Engine Uses SAE 10W30 Oil
OPERATION
MUFFLER
AIR CLEANER THROTTLE LEVER
OIL ALERT LAMP
ENGINE SWITCH
CIRCUIT BREAKER
RECOIL STARTER
STARTER GRIP
FUEL VALVE
CHOKE LEVER
SPARK PLUG
(QAE TYPE)
(QAE TYPE)