17
How to use.
Mode control
Summer
Summer Eco Comfort
Normal
Normal
Select,
Select,
Pax Eos 100
Pax Eos 100H
Normal -
Summer -
Eco -
only Pax
Eos 100H
Comfort -
only Pax
Eos 100H
UK
- Main unit
Push choice of Mode location.
Normal Summer Eco Comfort
Normal Summer
Pax Eos 100
- Remote control
Pax Eos 100H
- Main unit
Puch choice of Mode location.
- Remote control
Continuous operation with heat exchange:
The Eos has normal heat exchange down to -15°C. From -15°C and down to -30°C, the Eos only working
with exhaust air. Between -20 to -30°C provided automatically 20m³/h extraction.
At -30 ° C stops Eos and dampers are closed.
Increased comfort in summer.
If Mode Summer is on and the outdoor air is 4°C colder than the exhaust air, the supply air stops and
the unit only work with exhaust air, apply at outdoor temperature down to 10°C.
(Otherwise similar mode Normal)
Only Eos with preheater: Continuous operation with heat exchange and limited supplementary heat.
The preheater heats as much as necessary to avoid icing / condensation in the heat exchanger.
The unit switches the air down to -20°C outdoor temperature, from -20 to -30°C provided
automatically 20m³/h extraction. At -30 ° C stops Eos and dampers are closed.
Only Eos with preheater: Increased comfort in winter, continuous operation with heat exchange and
supplementary heat.
The preheater heats as much as needed to keep supply air above +18 ° C.
The unit switches the air down to -20°C outdoor temperature, from -20 to -30°C provided
automatically 20m³/h extraction. At -30°C stops Eos and dampers are closed.