37
Technical specification.
GB
Model Name Pax Eos 100 Pax Eos 100H
Model Number 1110-1 1110-2
Model type Standard Standard with pre heater
Voltage / Frequency [V] [Hz] 230VAC 50Hz
Free blowing capacity [m³/h] 20 40 60 *80 20 40 60 *80
Power consumtion [W] 3,0 7,5 16 25 3,5 8,0 18 25
When the heater is on [W] - 375 -
UK
Noise pressure level [dB(A)] 3m 18 21 27 35 19 22 29 35
Heat recovery eciency [%] 80 78 75 - 80 78 75 -
Leakage [%] 5
Motor type DC motor
Encloser class IP24
Insulation class (class II)
Certified Intertek
Other labels
Filter OA: G4 / RA: G4
Unit wight [kg] 9 9,5
Installation Qualified installer
* Only exhaust blowing
D
If you feel that the ventilation fan is not working properly, check out the following points first.
If the truble persists, turn of the power switch and contact your dealer or an authorized
service centre.
General:
If you hear unusual sounds from the ventilation fan.
- Are ventilation- unit been installed on a sturdy and level ceiling/wall?
- It´s normal to hear some noises when the ventilation starts or stops.
The LED light does not come on.
- Is the power to the ventilation on?
-Check your home’s internal fuses.
Filter maintenance lamp blinks.
- Check the filters and replace with new filters.
The unit can not be operated by remote control.
- Are the batteries exhausted?
FAQs