Firmware update
The firmware of APEX 7000 can be updated with the handheld programmer “PRO-2” (optional).
Connect PRO-2” to the 6-pole connector located on the right side of the acceptor (under the label "
FLASH
MEMORY PORT
").
The programmer must be connected to a PC to load the correct firmware file, then disconnect PRO-2 from the
PC. After the firmware file has been successfully loaded on PRO-2, the bill acceptor can be easily updated with
PRO-2 on site (there is no need to have the PC at hand).
For more detailed info, please read “PRO-2” user guide.
Maintenance
The Apex bill acceptor is relatively maintenance free. An occasional cleaning is all that is needed to keep the
acceptor in top operation.
To clean the acceptor:
Remove power from the machine or unplug the MDB cable from the bill acceptor.
Unlatch the stacker by pushing in the yellow top latch and lifting the stacker up and out.
Remove the Lower Transport by pushing in the latch located on the bottom of the acceptor at the rear.
Gently pull the Lower Transport out of the assembly.
Clean the bill path using a soft cloth or towel.
Always use water.
If 100% water is not enough, use a mixture of water and alcool (80% water and 20% alcool).
Never use oils, benzene, or silicon spray on any part of the acceptor!