EasyManua.ls Logo

PCB Piezotronics 441A35 - Command Set

Default Icon
143 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
443B101/443B102 9
Manual 19854 Rev. D
ECN 50523
Command Set
This list of commands is the currently supported set that is applicable to the 443B101 and 443B102 Dual Mode Amplifier
modules.
Command: MMOD
Purpose: This command returns the module type of the card at the location specified by the
command.
Response: The response string is 3 ASCII printable characters that correspond to the module type
of the module at the location specified by the command.
Command Attribute: This command is supported by all modules using the protocol defined for the 441 series
racks (it is a common or “CMM” command).
Command String: XYCMMMMOD
Description: XRack number of the target module (Range: ASCII printable characters, 0 through 3)
Y Slot number of the target module. (Range: ASCII printable characters, 0 through 7)
CMMModule type for the target. Specifying "CMM" in this argument indicates the
intention of any module type that may be found in Rack X, Slot Y. (Range: 3 ASCII
printable characters)
MMODCommands target module to return its 3 character module type.
Response String: “C01” for 443B101 and “C02” for 443B102
Description: These 3 ASCII printable characters are the module type of the module at the location
specified by the command.
Example: Command String: “02CMMMOD”
Response String: “C02”
The module type of the card in rack 0 and slot 2 is a C02 (443B102).