If unable to turn o low speed, note the pump will connue to operate on low speed unl set temp is reached. It will automacal-
ly turn o when temp is reached.
Freeze Protecon
If the temperature sensors within the heater detect a low enough temperature, then the pump will automacally acvate to
provide freeze protecon. The pump will run either connuously or periodically depending on condions.
Clean-up Cycle
When a pump is turned on by a buon press, a clean-up cycle begins 30 minutes aer the pump is turned o or mes out. The
pump and the ozone generator will run for 30 minutes or more, depending on the system.
Temperature and Temp
Adjusng the Set Temperature
The panel has Up and Down buons (Temperature buons), pressing Up or Down will cause the temperature to ash. Pressing
a temperature buon again will adjust the set temperature in the direcon indicated on the buon. When the LCD stops ashing,
the spa will heat to the new set temperature when required. Spa temperature can be set between 80°F and 104°F.
Press-and-Hold
If a Temperature buon is pressed and held when the temperature is ashing, the temperature will connue to change unl the
buon is released.
NOTE: Spa will not reach set temp if unit is in Low Range. Check sengs to be sure unit is in High Range to reach temps above
80°F.
Dual Temperature Ranges
This system incorporates two temperature range sengs with independent set temperatures. The High Range designated in the
display by an “up” arrow, and the Low Range designated in the display by a “down” arrow.
These ranges can be used for various reasons, with a common use being a “ready to use” seng vs. a “vacaon” seng. The
Ranges are chosen using the menu structure below. Each range maintains its own set temperature as programmed by the user.
This way, when a range is chosen, the spa will heat to the set temperature associated with that range. For example: High range
might be set between 80°F and 104°F. Low range might be set between 50°F and 99°F. Freeze protecon is acve in either range.
1) Press menu key TEMP will be displayed.
2) Use Up or Down arrow to change from High to Low range. A small Up arrow or Down arrow icon will be displayed on the
screen.
NOTE: Spa will not reach set temp if unit is in Low Range. Check sengs to be sure unit is in High Range to reach temps above
80°F.
Mode, Ready and Rest
In order for the spa to heat, a pump needs to circulate water through the heater. The pump that performs this funcon is known
as the “heater pump.”
READY Mode will circulate water periodically, using pump Low, in order to maintain a constant water temperature, heat as needed,
and refresh the temperature display. This is known as “polling.”
REST Mode will only allow heang during programmed filter cycles. Since polling does not occur, the temperature display may not
show a current temperature unl the pump has been running for a minute or two.
Ready-in-Rest Mode
READY/REST appears in the display if the spa is in Rest Mode and Jet 1 is pressed. It is assumed that the spa is being used and will
heat to set temperature. While Pump High can be turned on and o, pump Low will run unl set temperature is reached, or 1 hour
has passed. Aer 1 hour, the System will revert to Rest Mode. This mode can also be reset by entering the Mode Menu and
changing the Mode.