414(A465)

Questions and Answers

  • T
    Terry WilkinsAug 5, 2025
    What to do if Peak AMGO 414 lift raises too slow?
    • J
      Joseph GrayAug 6, 2025
      If your Peak Lifting System lift raises too slowly, it could be due to several reasons: the oil line might be jammed (clean the oil line); the motor might be running on low voltage (check the electrical system); the oil might be mixed with air (fill the tank); the pump might be leaking (replace pump); or you might be experiencing overload lifting (check load).
  • S
    Stacie FrostAug 11, 2025
    What to do if Peak AMGO 414 Lifting Systems lift does not stay up?
    • M
      Molly CarrollAug 11, 2025
      If your Peak Lifting System lift doesn't stay up, it could be because the solenoid valve is out of work (repair or replace it), there is a relief valve or check valve leakage (repair or replace), or the cylinder or fittings leak (repair or replace).
  • J
    Jack WebbAug 18, 2025
    What to do if Peak AMGO 414 lift cannot lower?
    • W
      williamselizabethAug 18, 2025
      If your Peak Lifting Systems lift cannot lower, the issue might stem from a damaged air solenoid valve (replace or repair), a damaged hydraulic solenoid valve (replace or repair), a damaged air cylinder (replace the cylinder), or a leak in the air-line (check the air-line).
  • L
    longrebekahAug 23, 2025
    Why Peak Lifting Systems motor does not run?
    • S
      shannonedwardsAug 23, 2025
      If the motor of your Peak Lifting System doesn't run, it could be due to several reasons: the button might not be working (replace it); the wiring connections might be in poor condition (repair all wiring connections); the motor could be burned out (repair or replace it); the AC contactor might be burned out (replace it); or the height limit switch might be damaged (replace it).
  • E
    Elizabeth HoffmanAug 29, 2025
    Why Peak AMGO 414 motor runs but the lift is not raised?
    • L
      Lisa ShafferAug 29, 2025
      If the motor runs but the Peak Lifting Systems lift is not raised, possible causes include: the motor running in reverse rotation (reverse two power wires); damage to the hydraulic solenoid valve (repair or replace); damage to the gear pump (repair or replace); damage to the relief valve or check valve (repair or replace); or a low oil level (fill the tank).

Summary

Installation Requirement

Tools Required for Installation

Lists all necessary tools for installing the lift.

Concrete Specifications for Installation

Details concrete thickness, strength, and levelness requirements.

Air Supply Requirements

Specifies air pressure and air line size requirements.

Power Supply Requirements

Outlines minimum power requirement and cable specification.

Steps of Installation

Site Selection and Layout

Verifies suitability of the installation site and marks precise placement.

Component Pre-Assembly Checks

Ensures all components are accounted for prior to assembly.

Establish installation layout

Marks the precise placement and dimensions for the lift.

Installing Cross Beams

Connects the cross beams to the main support columns.

Securing Anchor Bolts

Secures the lift structure to the floor using anchor bolts.

Installing Safety Ladders

Mounts the safety locking mechanisms onto the columns.

Synchronizing Cross Beam Height

Ensures both cross beams are at the same level for operation.

Powerside Platform Installation

Attaches the platform used for lifting vehicles.

Offside Platform and Slider Block Assembly

Installs the offside platform and checks column verticality.

Cable Routing and Securing

Routes and secures all necessary lift operating cables.

Control Box and Power Unit Installation

Mounts and connects the main control and power systems.

Hydraulic System Assembly

Connects hydraulic components for lift actuation.

Air-Line System Installation

Connects pneumatic lines for air-actuated features.

Electric System Installation

Installs limit switches and wiring for electrical control.

Spring and Safety Cover Installation

Attaches springs and protective covers to the cross beam assembly.

Ramps and Tire Stop Plate Installation

Mounts drive-in ramps and tire stop plates for vehicle positioning.

Optional Air Line Kit Installation

Details the installation of optional pneumatic line kits.

Test Run

Limit Switch Adjustment

Calibrates limit switches for proper safety lock function.

Operation Instructions

Lifting Vehicle Procedure

Step-by-step process for safely raising a vehicle.

Lowering Vehicle Procedure

Step-by-step process for safely lowering a vehicle.

Maintenance Schedule

Monthly Maintenance Tasks

Regular tasks for monthly upkeep and inspection.

Semi-Annual Maintenance Tasks

Periodic tasks for semi-annual inspection and maintenance.