Peak Atlas LCR
Passive Component Analyser
Model LCR40
Designed and manufactured with pride in the UK
User Guide
© Peak Electronic Design Limited 2002/2015
In the interests of development, information in this guide is subject to change without notice - E&OE
GB40-6

Questions and Answers

  • B
    Brenda GrayJul 28, 2025
    What to do if measured value doesn’t appear to be correct on Peak Measuring Instruments?
    • K
      Kathryn CooperJul 28, 2025
      If the measured value on your Peak Measuring Instruments doesn't seem right, ensure the probes are securely connected to the component throughout the test. Also, verify that the component under test isn't connected to anything else and that you're not touching the connections. The component value might be outside the measurable range, or its design frequency may not match the test frequencies of the Atlas LCR.
  • A
    amber75Aug 2, 2025
    Why calibration date is approaching or has past on Peak Atlas LCR40 Measuring Instruments?
    • T
      Tina BurchAug 2, 2025
      Don't be concerned if the calibration date for your Peak Atlas LCR Measuring Instruments is near or has passed. The device will continue to function normally. The date serves merely as a recommendation.
  • M
    Michael HarrisAug 8, 2025
    Why do measured values vary slightly between tests on Peak Atlas LCR40 Measuring Instruments?
    • C
      chancarlosAug 9, 2025
      Small variations within the quoted measurement resolutions are normal. The displayed resolution is higher than the measurement resolution to avoid rounding errors.
  • S
    Steven GallegosAug 14, 2025
    How to fix capacitance measured when probes are open circuit is not close to zero on Peak Atlas LCR40?
    • K
      Kara DurhamAug 14, 2025
      Perform a probe compensation on your Peak Measuring Instruments.
  • K
    Kayla LewisAug 20, 2025
    How to fix resistance and/or inductance measured when probes are short circuit is not close to zero on Peak Atlas LCR40?
    • B
      Brian SchmidtAug 20, 2025
      Perform a probe compensation on your Peak Measuring Instruments.

Summary

Introduction to the Atlas LCR

Important Notices and Warnings

Using Your Atlas LCR

Probe Compensation Procedure

Testing Inductors with Atlas LCR

Testing Capacitors with Atlas LCR

Testing Low Value Capacitors

Testing Large Capacitors

Testing Resistors

Low Resistance and Inductance Testing

Addresses low value inductors and resistors as a special case for testing.

Taking Care of Your Atlas LCR

Battery Replacement Guide

Instructions for replacing the device's battery and details on suitable battery types.

Atlas LCR Self Tests

Appendix A: Accessories

Appendix B: Component Identification

Inductor and Resistor Detection

Criteria for distinguishing between inductors and resistors based on measured values.

Capacitor and Resistor Detection Criteria

Appendix C: Technical Specifications

Appendix D: Troubleshooting

Appendix E: Warranty Information

Appendix F: Disposal Information

Peak Atlas LCR40 Specifications

General IconGeneral
Measurement ParametersInductance, Capacitance, Resistance
Inductance Range1 µH to 10 H
Resistance Range1 Ω to 2 MΩ
AccuracyTypically 1%
Dimensions103 mm x 70 mm x 20 mm
Test Frequency1kHz
DisplayAlphanumeric LCD