EasyManuals Logo

PeakTech 1035 User Manual

PeakTech 1035
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
* Disconnect test leads or probe from the measuring circuit before
switching modes or functions.
* Do not conduct voltage measurements with the test leads
connected to the mA/A- and COM-terminal of the equipment.
* To avoid electric shock, disconnect power to the unit under test
and discharge all capacitors before taking any resistance
measurements.
* Do not conduct current measurements with the leads connected
to the V/-terminals of the equipment.
* Check test leads and probes for faulty insulation or bare wires
before connection to the equipment.
* To avoid electric shock, do not operate this product in wet or
damp conditions. Conduct measuring works only in dry clothing
and rubber shoes, i. e. on isolating mats.
* Never touch the tips of the test leads or probe.
* Comply with the warning labels and other info on the equipment.
* Always start with the highest measuring range when measuring
unknown values.
* Do not subject the equipment to direct sunlight or extreme
temperatures, humidity or dampness.
* Do not subject the equipment to shocks or strong vibrations.
* Do not operate the equipment near strong magnetic fields
(motors, transformers etc.).
* Keep hot soldering irons or guns away from the equipment.
* Allow the equipment to stabilize at room temperature before
taking up measurement (important for exact measurements).
* Do not input values over the maximum range of each
measurement to avoid damages of the meter.
* Do not turn the rotary function switch during voltage or current
measurement, otherwise the meter could be damaged.
* Use caution when working with voltages above 35V DC or 25V
AC. These Voltages pose shock hazard.
* Replace the battery as soon as the battery indicator “BAT”
appears. With a low battery, the meter might produce false
reading that can lead to electric shock and personal injury.
-16-

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PeakTech 1035 and is the answer not in the manual?

PeakTech 1035 Specifications

General IconGeneral
Product typeDigital multimeter
DC voltage range600 V
Resistance range0.1 - 2000 Ω
Battery test modeYes
Measuring categoryCAT III 600V
Placement supportedHandheld multimeter
Battery test mode range1.5 - 9 V
Resolution (AC voltage)100 mV
Resolution (DC current)2000 µA
Resolution (DC voltage)200 mV
Basic accuracy (DC current)+/- 0.5%
Battery type9V
Power sourceBattery