Type | Digital Multimeter |
---|---|
DC Voltage Accuracy | ±(0.5% + 2 digits) |
Resistance Accuracy | ±(0.8% + 2 digits) |
Frequency Range | 10Hz to 10MHz |
Diode Test | Yes |
Continuity Test | Yes |
hFE Test | Yes |
Power Supply | 9V battery |
Display | 3 5/6-digit LCD, 6000 counts |
DC Voltage Range | 600mV, 6V, 60V, 600V, 1000V |
DC Current Range | 600 µA / 6000 µA / 60 mA / 600 mA / 6 A / 10 A |
DC Current Accuracy | ±(1.0% + 3 digits) |
AC Current Range | 600 µA / 6000 µA / 60 mA / 600 mA / 6 A / 10 A |
Resistance Range | 600Ω, 6kΩ, 60kΩ, 600kΩ, 6MΩ, 60MΩ |
Frequency Accuracy | ±(1.0% + 5 digits) |
Temperature Range | -40°C to 1000°C |
Temperature Accuracy | ±(1.0% + 3 digits) |
Specifies the maximum voltage and current allowed for safe measurements.
Explanation of warning and caution symbols used in the manual and on the device.
Identification and description of buttons, display, and ports on the multimeter's front.
Important notes before starting operation, including power and warning signs.
How to switch between automatic and manual selection of measurement ranges.
Explanation of the functions of the F1-F4, RANGE, and HOLD/REL buttons.
Details on interpreting the information shown on the TFT/LCD display.
Guide to selecting measurement functions using the rotary switch.
Instructions for connecting test leads to the correct input jacks.
How to record and display minimum and maximum measured values.
Procedure for capturing and displaying peak voltage or current values.
Using the relative mode to measure the difference from a reference value.
How to freeze and save the current measurement reading on the display.
Guides for measuring DC and AC voltages, including mV ranges.
Steps to measure the frequency of electrical signals.
How to safely measure resistance and perform continuity tests.
How to test the functionality of diodes and semiconductor junctions.
Steps for measuring the capacitance of electronic components.
How to measure temperature using the K-type thermocouple.
Procedure for measuring DC current, including range selection.
Instructions for measuring AC current, including range and safety.
How to measure current in the 4-20mA standard for industrial signals.
How to activate and use the graphical measurement mode.
Procedure for saving a single measured value into the meter's memory.
How to retrieve and view previously stored measurement data.
How to view stored graphical measurement recordings.
Setting up and starting a data recording session for measurements.
How to view recorded data trends over time.
How to restore the meter to its factory default settings.
Configuring display formats for beeper, numeric, date, and time.
Adjusting display settings, date, time, and auto power off.
Overview of the meter's technical specifications and capabilities.
Detailed technical specifications including ranges, resolution, and accuracy.