Page #6 background image
DC Current
Range
Accuracy
Resolution
2000 µA
± 1,0 % + 2 digit
1 µA
20 mA
10 µA
200 mA
± 1,2 % + 2 digit
100 µA
10 A
± 2,0 % + 2 digit
10 mA
Overload protection: µA/mA-ranges: 0,5 A/600 V fuse
10A-ranges: 10A/600V fuse
maximum input current: 10 A
Resistance
Range
Accuracy
Resolution
200 Ω
± 0.8 % + 8 digit
0.1 Ω
2000 Ω
± 0.8 % + 2 digit
1 Ω
20 kΩ
10 Ω
200 kΩ
100 Ω
2000 kΩ
± 1,0 % + 2 digit
1 kΩ
Max. open circuit: under 2,8 V
Overload protection: 220 V
rms
in all ranges (max. 15 sec.)
Diode Test
Range
Description
Test Conditions
Display read approx.
forward voltage of
diode
Forward DC current
1 mA.
Reversed DC voltage
approx. 2,8 V.
-19-

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PeakTech 1035 and is the answer not in the manual?

PeakTech 1035 Specifications

General IconGeneral
Product typeDigital multimeter
DC voltage range600 V
Resistance range0.1 - 2000 Ω
Battery test modeYes
Measuring categoryCAT III 600V
Placement supportedHandheld multimeter
Battery test mode range1.5 - 9 V
Resolution (AC voltage)100 mV
Resolution (DC current)2000 µA
Resolution (DC voltage)200 mV
Basic accuracy (DC current)+/- 0.5%
Battery type9V
Power sourceBattery