7.9. Making Automatic Measurements
The oscilloscope can perform 18 types automatic measurements such as frequency, cycle, average value, peak-to-peak
value , root mean square value, Vmax, Vmin, Vtop, Vbase, Vamp, Overshoot, Preshoot, RiseTime, Fall Time, +Width,
-Width, +Duty, -Duty, and gives two kinds of measurement results simultaneously on the screen.
The function menu for automatic measurements is described in the following list.
To measure the average value with Measurement 1 and the peak-to-peak value with Measurement 2, do the following:
1. Press the MENU key and the function menu is shown at the right of the screen.
2. Press the MENU ▲ or MENU ▼ key to select MEAS SET1. Five options appear at the bottom of the screen.
3. Press the F1 key to select the frequency measurement. The measurement window on the screen shows the
frequency of waveform.
4. Press the MENU ▲ or MENU ▼ key to select MEAS SET 2. Five options appear at the bottom of the screen.
5. Press the F4 key to jump to the PK-PK measurement. The measurement window on the screen shows the
peak-to-peak value of waveform.
Now, you can see a screen that looks like the following figure 44.
Figure 44: Automatic Measurements
-105-