7.3.2. Video Triggering
With Video triggering selected, the oscilloscope performs the NTSC, PAL or SECAM standard video signals field , line ,odd
field, even field or line num trigger.
Figure 35 is the Video Odd Field Trigger, Figure 36, Figure 37 is the Video Line trigger.
Figure 35: Video Odd Field Trigger
Figure 36: Video Line NO. trigger (Page1) Figure 37: Video Line NO. trigger (Page2)
The Video trigger menu is described in the following table (first page):
Function
menu
Settings
Description
Sync
Line
Make a video line trigger synchronization setting.
Field
Make a video field trigger synchronization setting.
Odd Field
Make a video odd field trigger synchronization setting.
Even Field
Make a video even field trigger synchronization setting.
Line Num
Make a video designed line synchronization setting.
MODU
NTSC
PAL/SECAM
Video format setting
Holdoff
To go to holdoff menu.
Back to previous menu (When Sync selected as LINE NUM)